Maxeon / SunPower SPR-MAX3-400
400 W, 112 cell monocrystalline module, white backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
400W / 379.4W
Efficiency
21.05%
Voc / Vmp
81.09V / 67.98V
Max String (600V)
6 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Maxeon / SunPower |
|---|---|
| Model Number (MPN) | SPR-MAX3-400 |
| Cell Technology | Mono-c-Si · 112 cells |
| Nameplate Power (Pmax STC) | 400 W |
| Real-World Output (PTC) | 379.4 W (94.8% of STC) |
| Module Efficiency | 21.05% (210.5 W/m²) |
| Open-Circuit Voltage (Voc) | 81.09 V |
| Maximum Power Voltage (Vmp) | 67.98 V |
| Short-Circuit Current (Isc) | 6.53 A (NEC 1.25× = 8.16 A) |
| Maximum Power Current (Imp) | 5.88 A |
| Temp. Coeff. Power (γPmax) | -0.272 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.233 %/°C |
| Temp. Coeff. Current (αIsc) | +0.056 %/°C |
| Nominal Cell Temp (NOCT) | 45 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 1.9 m² (20.5 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.233%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 81.09 V | 7 | 12 |
| 0°C / 32°F Freezing / Mild Winter | 85.81 V | 6 | 11 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 87.7 V | 6 | 11 |
| -20°C / -4°F Northeast / Midwest Winter | 89.59 V | 6 | 11 |
| -30°C / -22°F Northern Plains / Mountain | 91.48 V | 6 | 10 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.00 kW | 307 sq ft (28.5 m²) |
| 8 kW | 20 panels | 8.00 kW | 409 sq ft (38.0 m²) |
| 10 kW | 25 panels | 10.00 kW | 511 sq ft (47.5 m²) |
| 12 kW | 30 panels | 12.00 kW | 614 sq ft (57.0 m²) |
Compatible CEC-Listed Inverters for SPR-MAX3-400
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 1–6 panels/string at -10°C | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 2–9 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 3–5 panels/string at -10°C | Verify Pair |
| Growatt SPH 3000TL BL-US | Hybrid | 2.934 kW | 93.5% | 3–5 panels/string at -10°C | Verify Pair |
| Growatt MIN 3000TL-XH-US | Hybrid | 3.095 kW | 97% | 3–5 panels/string at -10°C | Verify Pair |
Other Power Classes in This Maxeon / SunPower Series (7 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| SPR-MAX3-410 | 410 W | 389.1 W | 6.53 V | 6.54 A | 21.58% |
| SPR-MAX3-415 | 415 W | 393.9 W | 81.23 V | 6.55 A | 21.84% |
| SPR-MAX3-420 | 420 W | 398.8 W | 81.27 V | 6.56 A | 22.11% |
| SPR-MAX3-425 | 425 W | 403.6 W | 81.32 V | 6.57 A | 22.37% |
| SPR-MAX3-430 | 430 W | 408.5 W | 81.36 V | 6.57 A | 22.63% |
| SPR-MAX3-435 | 435 W | 413.3 W | 81.4 V | 6.58 A | 22.89% |
Engineering FAQ — Maxeon / SunPower SPR-MAX3-400
How many Maxeon / SunPower SPR-MAX3-400 panels can fit in one 600V string?
At -10°C (14°F) ambient, the SPR-MAX3-400 open-circuit voltage rises from 81.09V to 87.7V (using βVoc -0.233%/°C), allowing up to 6 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Maxeon / SunPower SPR-MAX3-400?
Rated at 400W STC, the SPR-MAX3-400 carries a 379.4W PTC rating (94.8% PTC/STC ratio) and 21.05% module efficiency across 1.9 m² (20.5 sq ft).
Is the Maxeon / SunPower SPR-MAX3-400 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.