Meyer Burger MB_WG144C2S_540
540 W, 144 half-cut cell bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
540W / 511.6W
Efficiency
20.61%
Voc / Vmp
53.4V / 45.3V
Max String (600V)
10 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | Meyer Burger |
|---|---|
| Model Number (MPN) | MB_WG144C2S_540 |
| Cell Technology | Mono-c-Si (Bifacial) · 144 cells |
| Nameplate Power (Pmax STC) | 540 W |
| Real-World Output (PTC) | 511.6 W (94.7% of STC) |
| Module Efficiency | 20.61% (206.1 W/m²) |
| Open-Circuit Voltage (Voc) | 53.4 V |
| Maximum Power Voltage (Vmp) | 45.3 V |
| Short-Circuit Current (Isc) | 12.7 A (NEC 1.25× = 15.88 A) |
| Maximum Power Current (Imp) | 11.9 A |
| Temp. Coeff. Power (γPmax) | -0.259 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.233 %/°C |
| Temp. Coeff. Current (αIsc) | +0.04 %/°C |
| Nominal Cell Temp (NOCT) | 46.2 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.62 m² (28.2 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.233%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 53.4 V | 11 | 18 |
| 0°C / 32°F Freezing / Mild Winter | 56.51 V | 10 | 17 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 57.75 V | 10 | 17 |
| -20°C / -4°F Northeast / Midwest Winter | 59 V | 10 | 16 |
| -30°C / -22°F Northern Plains / Mountain | 60.24 V | 9 | 16 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 12 panels | 6.48 kW | 338 sq ft (31.4 m²) |
| 8 kW | 15 panels | 8.10 kW | 423 sq ft (39.3 m²) |
| 10 kW | 19 panels | 10.26 kW | 536 sq ft (49.8 m²) |
| 12 kW | 23 panels | 12.42 kW | 649 sq ft (60.3 m²) |
Compatible CEC-Listed Inverters for MB_WG144C2S_540
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.41 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–13 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This Meyer Burger Series (5 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| MB_WG144C2S_545 | 545 W | 516.5 W | 53.4 V | 12.8 A | 20.8% |
| MB_WG144C2S_550 | 550 W | 521.3 W | 53.4 V | 12.9 A | 20.99% |
| MB_WG144C2S_555 | 555 W | 526.2 W | 53.5 V | 13 A | 21.18% |
| MB_WG144C2S_560 | 560 W | 531 W | 53.5 V | 13.1 A | 21.37% |
Engineering FAQ — Meyer Burger MB_WG144C2S_540
How many Meyer Burger MB_WG144C2S_540 panels can fit in one 600V string?
At -10°C (14°F) ambient, the MB_WG144C2S_540 open-circuit voltage rises from 53.4V to 57.75V (using βVoc -0.233%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Meyer Burger MB_WG144C2S_540?
Rated at 540W STC, the MB_WG144C2S_540 carries a 511.6W PTC rating (94.7% PTC/STC ratio) and 20.61% module efficiency across 2.62 m² (28.2 sq ft).
Is the Meyer Burger MB_WG144C2S_540 listed in the CEC registry for US residential designs?
No — this model is categorized as Legacy / Replacement Reference (UL 61730). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.