Mission Solar MSE460HT2B
460 W, 120 half-cut cell monocrystalline module, 1000V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
460W / 431.3W
Efficiency
21.9%
Voc / Vmp
41.64V / 34.55V
Max String (600V)
13 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Mission Solar |
|---|---|
| Model Number (MPN) | MSE460HT2B |
| Cell Technology | Mono-c-Si · 120 cells |
| Nameplate Power (Pmax STC) | 460 W |
| Real-World Output (PTC) | 431.3 W (93.8% of STC) |
| Module Efficiency | 21.9% (219 W/m²) |
| Open-Circuit Voltage (Voc) | 41.64 V |
| Maximum Power Voltage (Vmp) | 34.55 V |
| Short-Circuit Current (Isc) | 13.97 A (NEC 1.25× = 17.46 A) |
| Maximum Power Current (Imp) | 13.31 A |
| Temp. Coeff. Power (γPmax) | -0.326 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.25 %/°C |
| Temp. Coeff. Current (αIsc) | +0.038 %/°C |
| Nominal Cell Temp (NOCT) | 45.5 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.1 m² (22.6 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.25%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 41.64 V | 14 | 24 |
| 0°C / 32°F Freezing / Mild Winter | 44.24 V | 13 | 22 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 45.28 V | 13 | 22 |
| -20°C / -4°F Northeast / Midwest Winter | 46.32 V | 12 | 21 |
| -30°C / -22°F Northern Plains / Mountain | 47.37 V | 12 | 21 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 14 panels | 6.44 kW | 316 sq ft (29.4 m²) |
| 8 kW | 18 panels | 8.28 kW | 407 sq ft (37.8 m²) |
| 10 kW | 22 panels | 10.12 kW | 497 sq ft (46.2 m²) |
| 12 kW | 27 panels | 12.42 kW | 610 sq ft (56.7 m²) |
Compatible CEC-Listed Inverters for MSE460HT2B
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–13 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–10 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7GPLUS-72-2-US | Microinverter | 0.298 kW | 97% | 1:1 micro pairing (1.54 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 4–17 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–10 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–10 panels/string at -10°C | Verify Pair |
Other Power Classes in This Mission Solar Series (5 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| MSE440HT2B | 440 W | 412.1 W | 41.01 V | 13.69 A | 20.95% |
| MSE445HT2B | 445 W | 416.9 W | 41.15 V | 13.75 A | 21.19% |
| MSE450HT2B | 450 W | 421.7 W | 41.29 V | 13.82 A | 21.43% |
| MSE455HT2B | 455 W | 426.5 W | 41.47 V | 13.89 A | 21.67% |
Engineering FAQ — Mission Solar MSE460HT2B
How many Mission Solar MSE460HT2B panels can fit in one 600V string?
At -10°C (14°F) ambient, the MSE460HT2B open-circuit voltage rises from 41.64V to 45.28V (using βVoc -0.25%/°C), allowing up to 13 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Mission Solar MSE460HT2B?
Rated at 460W STC, the MSE460HT2B carries a 431.3W PTC rating (93.8% PTC/STC ratio) and 21.9% module efficiency across 2.1 m² (22.6 sq ft).
Is the Mission Solar MSE460HT2B listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.