MSquare Energy Pty MGS-N-500W-60H
500 W, 120 half-cut cell double glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
500W / 475W
Efficiency
23.15%
Voc / Vmp
44.7V / 37.42V
Max String (600V)
12 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | MSquare Energy Pty |
|---|---|
| Model Number (MPN) | MGS-N-500W-60H |
| Cell Technology | Mono-c-Si · 120 cells |
| Nameplate Power (Pmax STC) | 500 W |
| Real-World Output (PTC) | 475 W (95% of STC) |
| Module Efficiency | 23.15% (231.5 W/m²) |
| Open-Circuit Voltage (Voc) | 44.7 V |
| Maximum Power Voltage (Vmp) | 37.42 V |
| Short-Circuit Current (Isc) | 14.2 A (NEC 1.25× = 17.75 A) |
| Maximum Power Current (Imp) | 13.38 A |
| Temp. Coeff. Power (γPmax) | -0.299 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.246 %/°C |
| Temp. Coeff. Current (αIsc) | +0.047 %/°C |
| Nominal Cell Temp (NOCT) | 43.4 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.16 m² (23.3 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.246%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 44.7 V | 13 | 22 |
| 0°C / 32°F Freezing / Mild Winter | 47.45 V | 12 | 21 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 48.55 V | 12 | 20 |
| -20°C / -4°F Northeast / Midwest Winter | 49.65 V | 12 | 20 |
| -30°C / -22°F Northern Plains / Mountain | 50.75 V | 11 | 19 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 12 panels | 6.00 kW | 279 sq ft (25.9 m²) |
| 8 kW | 16 panels | 8.00 kW | 372 sq ft (34.6 m²) |
| 10 kW | 20 panels | 10.00 kW | 465 sq ft (43.2 m²) |
| 12 kW | 24 panels | 12.00 kW | 558 sq ft (51.8 m²) |
Compatible CEC-Listed Inverters for MGS-N-500W-60H
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–12 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.30 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 4–16 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–10 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–10 panels/string at -10°C | Verify Pair |
Other Power Classes in This MSquare Energy Pty Series (7 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| MGS-N-470W-60H | 470 W | 445.9 W | 43.5 V | 13.78 A | 21.76% |
| MGS-N-475W-60H | 475 W | 450.7 W | 43.7 V | 13.85 A | 21.99% |
| MGS-N-480W-60H | 480 W | 455.6 W | 43.9 V | 13.92 A | 22.22% |
| MGS-N-485W-60H | 485 W | 460.4 W | 44.1 V | 13.99 A | 22.45% |
| MGS-N-490W-60H | 490 W | 465.3 W | 44.3 V | 14.06 A | 22.69% |
| MGS-N-495W-60H | 495 W | 470.2 W | 44.5 V | 14.13 A | 22.92% |
Engineering FAQ — MSquare Energy Pty MGS-N-500W-60H
How many MSquare Energy Pty MGS-N-500W-60H panels can fit in one 600V string?
At -10°C (14°F) ambient, the MGS-N-500W-60H open-circuit voltage rises from 44.7V to 48.55V (using βVoc -0.246%/°C), allowing up to 12 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the MSquare Energy Pty MGS-N-500W-60H?
Rated at 500W STC, the MGS-N-500W-60H carries a 475W PTC rating (95% PTC/STC ratio) and 23.15% module efficiency across 2.16 m² (23.3 sq ft).
Is the MSquare Energy Pty MGS-N-500W-60H listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.