Mundra Solar PV (Adani) AB-G12R-132-590
590 W, 132 half-cut bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
590W / 556.9W
Efficiency
22.01%
Voc / Vmp
47.8V / 39.7V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Mundra Solar PV (Adani) |
|---|---|
| Model Number (MPN) | AB-G12R-132-590 |
| Cell Technology | Mono-c-Si (Bifacial) · 132 cells |
| Nameplate Power (Pmax STC) | 590 W |
| Real-World Output (PTC) | 556.9 W (94.4% of STC) |
| Module Efficiency | 22.01% (220.1 W/m²) |
| Open-Circuit Voltage (Voc) | 47.8 V |
| Maximum Power Voltage (Vmp) | 39.7 V |
| Short-Circuit Current (Isc) | 15.72 A (NEC 1.25× = 19.65 A) |
| Maximum Power Current (Imp) | 14.87 A |
| Temp. Coeff. Power (γPmax) | -0.284 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.232 %/°C |
| Temp. Coeff. Current (αIsc) | +0.042 %/°C |
| Nominal Cell Temp (NOCT) | 46.2 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.68 m² (28.8 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.232%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 47.8 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 50.57 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 51.68 V | 11 | 19 |
| -20°C / -4°F Northeast / Midwest Winter | 52.79 V | 11 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 53.9 V | 11 | 18 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 11 panels | 6.49 kW | 317 sq ft (29.5 m²) |
| 8 kW | 14 panels | 8.26 kW | 404 sq ft (37.5 m²) |
| 10 kW | 17 panels | 10.03 kW | 490 sq ft (45.6 m²) |
| 12 kW | 21 panels | 12.39 kW | 606 sq ft (56.3 m²) |
Compatible CEC-Listed Inverters for AB-G12R-132-590
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.54 DC/AC ratio) | Verify Pair |
| Fronius Primo GEN24 6.0 208-240 Plus SC | Hybrid | 6.005 kW | 97% | 4–11 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This Mundra Solar PV (Adani) Series (7 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| AB-G12R-132-595 | 595 W | 561.7 W | 48.1 V | 15.76 A | 22.2% |
| AB-G12R-132-600 | 600 W | 566.5 W | 48.4 V | 15.8 A | 22.39% |
| AB-G12R-132-605 | 605 W | 571.4 W | 48.7 V | 15.83 A | 22.57% |
| AB-G12R-132-610 | 610 W | 576.2 W | 49 V | 15.86 A | 22.76% |
| AB-G12R-132-615 | 615 W | 581 W | 49.3 V | 15.89 A | 22.95% |
| AB-G12R-132-620 | 620 W | 585.9 W | 49.6 V | 15.91 A | 23.13% |
Engineering FAQ — Mundra Solar PV (Adani) AB-G12R-132-590
How many Mundra Solar PV (Adani) AB-G12R-132-590 panels can fit in one 600V string?
At -10°C (14°F) ambient, the AB-G12R-132-590 open-circuit voltage rises from 47.8V to 51.68V (using βVoc -0.232%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Mundra Solar PV (Adani) AB-G12R-132-590?
Rated at 590W STC, the AB-G12R-132-590 carries a 556.9W PTC rating (94.4% PTC/STC ratio) and 22.01% module efficiency across 2.68 m² (28.8 sq ft).
Is the Mundra Solar PV (Adani) AB-G12R-132-590 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.