New East Solar Energy (Cambodia) NESE450-54THB-M10
450 W, 108 half-cut cell double glass monocrystalline module, 1500 max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
450W / 427.2W
Efficiency
23.2%
Voc / Vmp
39.2V / 32.7V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | New East Solar Energy (Cambodia) |
|---|---|
| Model Number (MPN) | NESE450-54THB-M10 |
| Cell Technology | Mono-c-Si · 108 cells |
| Nameplate Power (Pmax STC) | 450 W |
| Real-World Output (PTC) | 427.2 W (94.9% of STC) |
| Module Efficiency | 23.2% (232 W/m²) |
| Open-Circuit Voltage (Voc) | 39.2 V |
| Maximum Power Voltage (Vmp) | 32.7 V |
| Short-Circuit Current (Isc) | 14.53 A (NEC 1.25× = 18.16 A) |
| Maximum Power Current (Imp) | 13.77 A |
| Temp. Coeff. Power (γPmax) | -0.298 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.238 %/°C |
| Temp. Coeff. Current (αIsc) | +0.035 %/°C |
| Nominal Cell Temp (NOCT) | 43.7 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.94 m² (20.9 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.238%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 39.2 V | 15 | 25 |
| 0°C / 32°F Freezing / Mild Winter | 41.53 V | 14 | 24 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 42.47 V | 14 | 23 |
| -20°C / -4°F Northeast / Midwest Winter | 43.4 V | 13 | 23 |
| -30°C / -22°F Northern Plains / Mountain | 44.33 V | 13 | 22 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 14 panels | 6.30 kW | 292 sq ft (27.2 m²) |
| 8 kW | 18 panels | 8.10 kW | 376 sq ft (34.9 m²) |
| 10 kW | 23 panels | 10.35 kW | 480 sq ft (44.6 m²) |
| 12 kW | 27 panels | 12.15 kW | 564 sq ft (52.4 m²) |
Compatible CEC-Listed Inverters for NESE450-54THB-M10
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–14 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8PLUS-72-2-US | Microinverter | 0.295 kW | 97% | 1:1 micro pairing (1.53 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 4–18 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
Other Power Classes in This New East Solar Energy (Cambodia) Series (8 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| NESE415-54THB-M10 | 415 W | 393.2 W | 37.8 V | 14.04 A | 21.39% |
| NESE420-54THB-M10 | 420 W | 398.1 W | 38 V | 14.11 A | 21.65% |
| NESE425-54THB-M10 | 425 W | 402.9 W | 38.2 V | 14.18 A | 21.91% |
| NESE430-54THB-M10 | 430 W | 407.8 W | 38.4 V | 14.25 A | 22.16% |
| NESE435-54THB-M10 | 435 W | 412.6 W | 38.6 V | 14.32 A | 22.42% |
| NESE440-54THB-M10 | 440 W | 417.5 W | 38.8 V | 14.39 A | 22.68% |
| NESE445-54THB-M10 | 445 W | 422.3 W | 39 V | 14.46 A | 22.94% |
Engineering FAQ — New East Solar Energy (Cambodia) NESE450-54THB-M10
How many New East Solar Energy (Cambodia) NESE450-54THB-M10 panels can fit in one 600V string?
At -10°C (14°F) ambient, the NESE450-54THB-M10 open-circuit voltage rises from 39.2V to 42.47V (using βVoc -0.238%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the New East Solar Energy (Cambodia) NESE450-54THB-M10?
Rated at 450W STC, the NESE450-54THB-M10 carries a 427.2W PTC rating (94.9% PTC/STC ratio) and 23.2% module efficiency across 1.94 m² (20.9 sq ft).
Is the New East Solar Energy (Cambodia) NESE450-54THB-M10 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.