NS CEC-Listed · ResidentialUL 61730

Nexora Solar NEXO-X-DB-Serise 565

565 W, 144 half-cut cell monocrystalline module, transparent backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .

STC / PTC Power
565W / 530W
Efficiency
22.07%
Voc / Vmp
50.8V / 42.5V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Nexora Solar NEXO-X-DB-Serise 565 — Illustrative category photo — not this exact model · Real commercial solar module installation
Illustrative category photo — not this exact model · Real commercial solar module installationWikimedia Commons — File:Dornbirn-Rhombergs Fabrik-photovoltaic systems-01ASD.jpg (CC BY-SA 4.0)
MODULE FOOTPRINT (144 CELLS) 1722mm (67.8") 1134mm (44.6") STC I–V CURVE & COLD VOC (−10°C) −10°C 55.08V Isc 14.07A MPP 565W (42.5V · 13.3A) Voc 50.8V DC Voltage (V) · Efficiency 22.07%

Electrical & Thermal Specifications (STC)

Nexora Solar NEXO-X-DB-Serise 565 Electrical and Mechanical Specifications
ManufacturerNexora Solar
Model Number (MPN)NEXO-X-DB-Serise 565
Cell TechnologyMono-c-Si · 144 cells
Nameplate Power (Pmax STC)565 W
Real-World Output (PTC)530 W (93.8% of STC)
Module Efficiency22.07% (220.7 W/m²)
Open-Circuit Voltage (Voc)50.8 V
Maximum Power Voltage (Vmp)42.5 V
Short-Circuit Current (Isc)14.07 A (NEC 1.25× = 17.59 A)
Maximum Power Current (Imp)13.3 A
Temp. Coeff. Power (γPmax)-0.32 %/°C
Temp. Coeff. Voltage (βVoc)-0.241 %/°C
Temp. Coeff. Current (αIsc)+0.044 %/°C
Nominal Cell Temp (NOCT)45.8 °C
Dimensions (L × W)1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet)
Surface Area2.56 m² (27.6 sq ft) (Est.)
Safety ListingUL 61730

NEC 690.7 Cold-Weather Voc Limits

Computed using this module’s βVoc (-0.241%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.

NEC 690.7 Cold-Weather String Voltage Limits for NEXO-X-DB-Serise 565
Design Cold TempCold VocMax / 600VMax / 1000V
25°C / 77°F
STC Lab Standard
50.8 V1119
0°C / 32°F
Freezing / Mild Winter
53.86 V1118
-10°C / 14°F
TX / Southeast / Mid-Atlantic
55.08 V1018
-20°C / -4°F
Northeast / Midwest Winter
56.31 V1017
-30°C / -22°F
Northern Plains / Mountain
57.53 V1017

Residential Array Roof Sizing

Residential Roof Footprint Estimates Using NEXO-X-DB-Serise 565
Target SizePanels NeededActual DCRoof Footprint
6 kW11 panels6.21 kW303 sq ft (28.2 m²)
8 kW15 panels8.47 kW413 sq ft (38.4 m²)
10 kW18 panels10.17 kW496 sq ft (46.1 m²)
12 kW22 panels12.43 kW606 sq ft (56.3 m²)

Compatible CEC-Listed Inverters for NEXO-X-DB-Serise 565

Open full string calculator with this panel →
Compatible US-Certified Inverters for Nexora Solar NEXO-X-DB-Serise 565
Inverter ModelTopologyAC OutputCEC Eff.Compatibility Check (−10°C)Action
APsystems ELS-3KHybrid3.685 kW94%2–10 panels/string at -10°CVerify Pair
EG4 Electronics IV-8000-HYB-AWHybrid7.863 kW96.5%6–8 panels/string at -10°CVerify Pair
Enphase Energy IQ8X-80-E-USMicroinverter0.384 kW97%1:1 micro pairing (1.47 DC/AC ratio)Verify Pair
Fronius Primo 5.0-1 208-240String5 kW96.5%3–14 panels/string at -10°CVerify Pair
GoodWe GEC5.0-1U-US20Hybrid4.983 kW96%3–8 panels/string at -10°CVerify Pair
GoodWe GW5000-SBP-US20Hybrid4.983 kW96%3–8 panels/string at -10°CVerify Pair

Other Power Classes in This Nexora Solar Series (10 total CEC variants)

Sibling Power Classes in the Nexora Solar Series
Series Variant ModelSTC PowerPTC PowerVocIscEfficiency
NEXO-X-DB-Serise 520520 W486.8 W49 V13.53 A20.31%
NEXO-X-DB-Serise 525525 W491.6 W49.2 V13.59 A20.51%
NEXO-X-DB-Serise 530530 W496.4 W49.4 V13.65 A20.7%
NEXO-X-DB-Serise 535535 W501.2 W49.6 V13.71 A20.9%
NEXO-X-DB-Serise 540540 W506 W49.8 V13.77 A21.09%
NEXO-X-DB-Serise 545545 W510.8 W50 V13.83 A21.29%
NEXO-X-DB-Serise 550550 W515.6 W50.2 V13.89 A21.48%
NEXO-X-DB-Serise 555555 W520.4 W50.4 V13.95 A21.68%
NEXO-X-DB-Serise 560560 W525.2 W50.6 V14.01 A21.88%

Engineering FAQ — Nexora Solar NEXO-X-DB-Serise 565

How many Nexora Solar NEXO-X-DB-Serise 565 panels can fit in one 600V string?
At -10°C (14°F) ambient, the NEXO-X-DB-Serise 565 open-circuit voltage rises from 50.8V to 55.08V (using βVoc -0.241%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Nexora Solar NEXO-X-DB-Serise 565?
Rated at 565W STC, the NEXO-X-DB-Serise 565 carries a 530W PTC rating (93.8% PTC/STC ratio) and 22.07% module efficiency across 2.56 m² (27.6 sq ft).
Is the Nexora Solar NEXO-X-DB-Serise 565 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.

More Nexora Solar Solar Panels

NEXO-X-NTDD-Serise 615 (615W)NEXO-X-NTDD-Serise 600 (600W)NEXO-X-NTDD-Serise 570 (570W)NEXO-X-DB-Serise 550 (550W)NEXO-X-NTDD-Serise 540 (540W)NEXO-X-DB-Serise 520 (520W)All Nexora Solar Equipment →