OP CEC-Listed · ResidentialUL 61730Bifacial

Oakridge Power OPA-HBDW560-182(72)

560 W, 144 half-cut cell double glass bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .

STC / PTC Power
560W / 526.5W
Efficiency
21.88%
Voc / Vmp
51.62V / 42.11V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Oakridge Power OPA-HBDW560-182(72) — Illustrative category photo — not this exact model · Real bifacial glass-glass solar photovoltaic modules
Illustrative category photo — not this exact model · Real bifacial glass-glass solar photovoltaic modulesWikimedia Commons — File:Agrivoltaics bifacial solar.webp (CC0)
MODULE FOOTPRINT (144 CELLS) 1722mm (67.8") 1134mm (44.6") STC I–V CURVE & COLD VOC (−10°C) −10°C 55.78V Isc 14.09A MPP 560W (42.11V · 13.3A) Voc 51.62V DC Voltage (V) · Efficiency 21.88%

Electrical & Thermal Specifications (STC)

Oakridge Power OPA-HBDW560-182(72) Electrical and Mechanical Specifications
ManufacturerOakridge Power
Model Number (MPN)OPA-HBDW560-182(72)
Cell TechnologyMono-c-Si (Bifacial) · 144 cells
Nameplate Power (Pmax STC)560 W
Real-World Output (PTC)526.5 W (94% of STC)
Module Efficiency21.88% (218.8 W/m²)
Open-Circuit Voltage (Voc)51.62 V
Maximum Power Voltage (Vmp)42.11 V
Short-Circuit Current (Isc)14.09 A (NEC 1.25× = 17.61 A)
Maximum Power Current (Imp)13.3 A
Temp. Coeff. Power (γPmax)-0.302 %/°C
Temp. Coeff. Voltage (βVoc)-0.23 %/°C
Temp. Coeff. Current (αIsc)+0.044 %/°C
Nominal Cell Temp (NOCT)46.2 °C
Dimensions (L × W)1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet)
Surface Area2.56 m² (27.6 sq ft) (Est.)
Safety ListingUL 61730

NEC 690.7 Cold-Weather Voc Limits

Computed using this module’s βVoc (-0.23%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.

NEC 690.7 Cold-Weather String Voltage Limits for OPA-HBDW560-182(72)
Design Cold TempCold VocMax / 600VMax / 1000V
25°C / 77°F
STC Lab Standard
51.62 V1119
0°C / 32°F
Freezing / Mild Winter
54.59 V1018
-10°C / 14°F
TX / Southeast / Mid-Atlantic
55.78 V1017
-20°C / -4°F
Northeast / Midwest Winter
56.96 V1017
-30°C / -22°F
Northern Plains / Mountain
58.15 V1017

Residential Array Roof Sizing

Residential Roof Footprint Estimates Using OPA-HBDW560-182(72)
Target SizePanels NeededActual DCRoof Footprint
6 kW11 panels6.16 kW303 sq ft (28.2 m²)
8 kW15 panels8.40 kW413 sq ft (38.4 m²)
10 kW18 panels10.08 kW496 sq ft (46.1 m²)
12 kW22 panels12.32 kW606 sq ft (56.3 m²)

Compatible CEC-Listed Inverters for OPA-HBDW560-182(72)

Open full string calculator with this panel →
Compatible US-Certified Inverters for Oakridge Power OPA-HBDW560-182(72)
Inverter ModelTopologyAC OutputCEC Eff.Compatibility Check (−10°C)Action
APsystems ELS-3KHybrid3.685 kW94%2–10 panels/string at -10°CVerify Pair
EG4 Electronics IV-8000-HYB-AWHybrid7.863 kW96.5%6–8 panels/string at -10°CVerify Pair
Enphase Energy IQ8X-80-E-USMicroinverter0.384 kW97%1:1 micro pairing (1.46 DC/AC ratio)Verify Pair
Fronius Primo 5.0-1 208-240String5 kW96.5%3–14 panels/string at -10°CVerify Pair
GoodWe GEC5.0-1U-US20Hybrid4.983 kW96%3–8 panels/string at -10°CVerify Pair
GoodWe GW5000-SBP-US20Hybrid4.983 kW96%3–8 panels/string at -10°CVerify Pair

Other Power Classes in This Oakridge Power Series (10 total CEC variants)

Sibling Power Classes in the Oakridge Power Series
Series Variant ModelSTC PowerPTC PowerVocIscEfficiency
OPA-HBDW565-182(72)565 W531.4 W51.82 V14.15 A22.07%
OPA-HBDW570-182(72)570 W536.2 W52.02 V14.21 A22.27%
OPA-HBDW575-182(72)575 W541 W52.22 V14.27 A22.46%
OPA-HBDW580-182(72)580 W545.9 W52.42 V14.33 A22.66%
OPA-HBDW585-182(72)585 W550.7 W52.62 V14.39 A22.85%
OPA-HBDW590-182(72)590 W555.5 W52.82 V14.45 A23.05%
OPA-HBDW595-182(72)595 W560.4 W53.02 V14.51 A23.24%
OPA-HBDW600-182(72)600 W565.2 W53.22 V14.57 A23.44%
OPA-HBDW605-182(72)605 W570 W53.42 V14.63 A23.63%

Engineering FAQ — Oakridge Power OPA-HBDW560-182(72)

How many Oakridge Power OPA-HBDW560-182(72) panels can fit in one 600V string?
At -10°C (14°F) ambient, the OPA-HBDW560-182(72) open-circuit voltage rises from 51.62V to 55.78V (using βVoc -0.23%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Oakridge Power OPA-HBDW560-182(72)?
Rated at 560W STC, the OPA-HBDW560-182(72) carries a 526.5W PTC rating (94% PTC/STC ratio) and 21.88% module efficiency across 2.56 m² (27.6 sq ft).
Is the Oakridge Power OPA-HBDW560-182(72) listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.

More Oakridge Power Solar Panels

OPA-HBDW605-210R(66) (605W)OPA-HBDW605-182(72) (605W)OPA-HBDW590-182(72) (590W)OPA-HBDW650-210R(66) (650W)OPA-HBDW635-210R(66) (635W)All Oakridge Power Equipment →