PEIMAR DR10H550M
550 W, 144 half-cut cell monocrystalline module, black backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
550W / 515.7W
Efficiency
21.48%
Voc / Vmp
49.6V / 40.9V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | PEIMAR |
|---|---|
| Model Number (MPN) | DR10H550M |
| Cell Technology | Mono-c-Si · 144 cells |
| Nameplate Power (Pmax STC) | 550 W |
| Real-World Output (PTC) | 515.7 W (93.8% of STC) |
| Module Efficiency | 21.48% (214.8 W/m²) |
| Open-Circuit Voltage (Voc) | 49.6 V |
| Maximum Power Voltage (Vmp) | 40.9 V |
| Short-Circuit Current (Isc) | 14.03 A (NEC 1.25× = 17.54 A) |
| Maximum Power Current (Imp) | 13.45 A |
| Temp. Coeff. Power (γPmax) | -0.355 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.306 %/°C |
| Temp. Coeff. Current (αIsc) | +0.055 %/°C |
| Nominal Cell Temp (NOCT) | 43.7 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.56 m² (27.6 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.306%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49.6 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 53.39 V | 11 | 18 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 54.91 V | 10 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 56.43 V | 10 | 17 |
| -30°C / -22°F Northern Plains / Mountain | 57.95 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 11 panels | 6.05 kW | 303 sq ft (28.2 m²) |
| 8 kW | 15 panels | 8.25 kW | 413 sq ft (38.4 m²) |
| 10 kW | 19 panels | 10.45 kW | 524 sq ft (48.6 m²) |
| 12 kW | 22 panels | 12.10 kW | 606 sq ft (56.3 m²) |
Compatible CEC-Listed Inverters for DR10H550M
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.43 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This PEIMAR Series (20 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| DR10H395M | 395 W | 369.9 W | 36.9 V | 13.71 A | 20.36% |
| DR10H400M | 400 W | 374.7 W | 37 V | 13.78 A | 20.62% |
| DR10H405M | 405 W | 379.5 W | 37.1 V | 13.85 A | 20.88% |
| DR10H410M | 410 W | 384.3 W | 37.1 V | 13.92 A | 21.13% |
| DR10H415M | 415 W | 389.1 W | 37.3 V | 14.01 A | 21.39% |
| DR10H440M | 440 W | 412.1 W | 41 V | 13.73 A | 20.56% |
| DR10H445M | 445 W | 416.9 W | 41.1 V | 13.79 A | 20.79% |
| DR10H450M | 450 W | 421.7 W | 41.2 V | 13.85 A | 21.03% |
| DR10H455M | 455 W | 426.5 W | 41.3 V | 13.93 A | 21.26% |
| DR10H460M | 460 W | 431.3 W | 41.5 V | 14.01 A | 21.5% |
| DR10H485M | 485 W | 454.2 W | 45.1 V | 13.67 A | 20.46% |
| DR10H490M | 490 W | 459 W | 45.25 V | 13.74 A | 20.68% |
| DR10H495M | 495 W | 463.8 W | 45.4 V | 13.82 A | 20.89% |
| DR10H500M | 500 W | 468.6 W | 45.45 V | 13.93 A | 21.1% |
Engineering FAQ — PEIMAR DR10H550M
How many PEIMAR DR10H550M panels can fit in one 600V string?
At -10°C (14°F) ambient, the DR10H550M open-circuit voltage rises from 49.6V to 54.91V (using βVoc -0.306%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the PEIMAR DR10H550M?
Rated at 550W STC, the DR10H550M carries a 515.7W PTC rating (93.8% PTC/STC ratio) and 21.48% module efficiency across 2.56 m² (27.6 sq ft).
Is the PEIMAR DR10H550M listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.