Philadelphia Solar PS-M132(HCBF)-500W
500 W, 132 half-cut cells monocrystalline module, transparent backsheet, 1500 max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
500W / 465.4W
Efficiency
23.04%
Voc / Vmp
45.69V / 37.75V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Philadelphia Solar |
|---|---|
| Model Number (MPN) | PS-M132(HCBF)-500W |
| Cell Technology | Mono-c-Si · 132 cells |
| Nameplate Power (Pmax STC) | 500 W |
| Real-World Output (PTC) | 465.4 W (93.1% of STC) |
| Module Efficiency | 23.04% (230.4 W/m²) |
| Open-Circuit Voltage (Voc) | 45.69 V |
| Maximum Power Voltage (Vmp) | 37.75 V |
| Short-Circuit Current (Isc) | 13.91 A (NEC 1.25× = 17.39 A) |
| Maximum Power Current (Imp) | 13.25 A |
| Temp. Coeff. Power (γPmax) | -0.37 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.286 %/°C |
| Temp. Coeff. Current (αIsc) | +0.045 %/°C |
| Nominal Cell Temp (NOCT) | 45.5 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.17 m² (23.4 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.286%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 45.69 V | 13 | 21 |
| 0°C / 32°F Freezing / Mild Winter | 48.96 V | 12 | 20 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 50.26 V | 11 | 19 |
| -20°C / -4°F Northeast / Midwest Winter | 51.57 V | 11 | 19 |
| -30°C / -22°F Northern Plains / Mountain | 52.88 V | 11 | 18 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 12 panels | 6.00 kW | 280 sq ft (26.0 m²) |
| 8 kW | 16 panels | 8.00 kW | 374 sq ft (34.7 m²) |
| 10 kW | 20 panels | 10.00 kW | 467 sq ft (43.4 m²) |
| 12 kW | 24 panels | 12.00 kW | 561 sq ft (52.1 m²) |
Compatible CEC-Listed Inverters for PS-M132(HCBF)-500W
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.30 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 4–15 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This Philadelphia Solar Series (3 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| PS-M132(HCBF)-505W | 505 W | 470.2 W | 45.86 V | 13.96 A | 23.27% |
| PS-M132(HCBF)-510W | 510 W | 475 W | 46.09 V | 14.01 A | 23.5% |
Engineering FAQ — Philadelphia Solar PS-M132(HCBF)-500W
How many Philadelphia Solar PS-M132(HCBF)-500W panels can fit in one 600V string?
At -10°C (14°F) ambient, the PS-M132(HCBF)-500W open-circuit voltage rises from 45.69V to 50.26V (using βVoc -0.286%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Philadelphia Solar PS-M132(HCBF)-500W?
Rated at 500W STC, the PS-M132(HCBF)-500W carries a 465.4W PTC rating (93.1% PTC/STC ratio) and 23.04% module efficiency across 2.17 m² (23.4 sq ft).
Is the Philadelphia Solar PS-M132(HCBF)-500W listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.