PowerShingle EJ-410-PS-M10-B
410 W, 108 cell monocrystalline module, black backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
410W / 385.5W
Efficiency
21.64%
Voc / Vmp
37.5V / 31.6V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | PowerShingle |
|---|---|
| Model Number (MPN) | EJ-410-PS-M10-B |
| Cell Technology | Mono-c-Si · 108 cells |
| Nameplate Power (Pmax STC) | 410 W |
| Real-World Output (PTC) | 385.5 W (94% of STC) |
| Module Efficiency | 21.64% (216.4 W/m²) |
| Open-Circuit Voltage (Voc) | 37.5 V |
| Maximum Power Voltage (Vmp) | 31.6 V |
| Short-Circuit Current (Isc) | 13.86 A (NEC 1.25× = 17.32 A) |
| Maximum Power Current (Imp) | 13 A |
| Temp. Coeff. Power (γPmax) | -0.319 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.244 %/°C |
| Temp. Coeff. Current (αIsc) | +0.04 %/°C |
| Nominal Cell Temp (NOCT) | 45 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 1.895 m² (20.4 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.244%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 37.5 V | 16 | 26 |
| 0°C / 32°F Freezing / Mild Winter | 39.79 V | 15 | 25 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 40.7 V | 14 | 24 |
| -20°C / -4°F Northeast / Midwest Winter | 41.62 V | 14 | 24 |
| -30°C / -22°F Northern Plains / Mountain | 42.53 V | 14 | 23 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.15 kW | 306 sq ft (28.4 m²) |
| 8 kW | 20 panels | 8.20 kW | 408 sq ft (37.9 m²) |
| 10 kW | 25 panels | 10.25 kW | 510 sq ft (47.4 m²) |
| 12 kW | 30 panels | 12.30 kW | 612 sq ft (56.9 m²) |
Compatible CEC-Listed Inverters for EJ-410-PS-M10-B
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–14 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.52 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 4–19 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–12 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–12 panels/string at -10°C | Verify Pair |
Other Power Classes in This PowerShingle Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| EJ-415-PS-M10-B | 415 W | 386.4 W | 38 V | 13.69 A | 21.39% |
| EJ-420-PS-M10-B | 420 W | 391.2 W | 38.3 V | 13.71 A | 21.65% |
| EJ-425-PS-M10-B | 425 W | 396 W | 38.4 V | 13.72 A | 21.91% |
| EJ-430-PS-M10-B | 430 W | 400.8 W | 38.6 V | 13.74 A | 22.16% |
| EJ-435-PS-M10-B | 435 W | 405.6 W | 38.7 V | 13.76 A | 22.42% |
Engineering FAQ — PowerShingle EJ-410-PS-M10-B
How many PowerShingle EJ-410-PS-M10-B panels can fit in one 600V string?
At -10°C (14°F) ambient, the EJ-410-PS-M10-B open-circuit voltage rises from 37.5V to 40.7V (using βVoc -0.244%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the PowerShingle EJ-410-PS-M10-B?
Rated at 410W STC, the EJ-410-PS-M10-B carries a 385.5W PTC rating (94% PTC/STC ratio) and 21.64% module efficiency across 1.895 m² (20.4 sq ft).
Is the PowerShingle EJ-410-PS-M10-B listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.