PE CEC-Listed · ResidentialUL 61730Bifacial

PREMIER ENERGIES PHOTOVOLTAIC PRIVATE PE-560HGB

560 W, 144 half-cut cell bifacial monocrystalline module 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .

STC / PTC Power
560W / 519.8W
Efficiency
21.88%
Voc / Vmp
49.91V / 41.43V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
PREMIER ENERGIES PHOTOVOLTAIC PRIVATE PE-560HGB — Illustrative category photo — not this exact model · Real bifacial glass-glass solar photovoltaic modules
Illustrative category photo — not this exact model · Real bifacial glass-glass solar photovoltaic modulesWikimedia Commons — File:Agrivoltaics bifacial solar.webp (CC0)
MODULE FOOTPRINT (144 CELLS) 1722mm (67.8") 1134mm (44.6") STC I–V CURVE & COLD VOC (−10°C) −10°C 54.89V Isc 14.21A MPP 560W (41.43V · 13.52A) Voc 49.91V DC Voltage (V) · Efficiency 21.88%

Electrical & Thermal Specifications (STC)

PREMIER ENERGIES PHOTOVOLTAIC PRIVATE PE-560HGB Electrical and Mechanical Specifications
ManufacturerPREMIER ENERGIES PHOTOVOLTAIC PRIVATE
Model Number (MPN)PE-560HGB
Cell TechnologyMono-c-Si (Bifacial) · 144 cells
Nameplate Power (Pmax STC)560 W
Real-World Output (PTC)519.8 W (92.8% of STC)
Module Efficiency21.88% (218.8 W/m²)
Open-Circuit Voltage (Voc)49.91 V
Maximum Power Voltage (Vmp)41.43 V
Short-Circuit Current (Isc)14.21 A (NEC 1.25× = 17.76 A)
Maximum Power Current (Imp)13.52 A
Temp. Coeff. Power (γPmax)-0.382 %/°C
Temp. Coeff. Voltage (βVoc)-0.285 %/°C
Temp. Coeff. Current (αIsc)+0.047 %/°C
Nominal Cell Temp (NOCT)45.1 °C
Dimensions (L × W)1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet)
Surface Area2.56 m² (27.6 sq ft) (Est.)
Safety ListingUL 61730

NEC 690.7 Cold-Weather Voc Limits

Computed using this module’s βVoc (-0.285%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.

NEC 690.7 Cold-Weather String Voltage Limits for PE-560HGB
Design Cold TempCold VocMax / 600VMax / 1000V
25°C / 77°F
STC Lab Standard
49.91 V1220
0°C / 32°F
Freezing / Mild Winter
53.47 V1118
-10°C / 14°F
TX / Southeast / Mid-Atlantic
54.89 V1018
-20°C / -4°F
Northeast / Midwest Winter
56.31 V1017
-30°C / -22°F
Northern Plains / Mountain
57.73 V1017

Residential Array Roof Sizing

Residential Roof Footprint Estimates Using PE-560HGB
Target SizePanels NeededActual DCRoof Footprint
6 kW11 panels6.16 kW303 sq ft (28.2 m²)
8 kW15 panels8.40 kW413 sq ft (38.4 m²)
10 kW18 panels10.08 kW496 sq ft (46.1 m²)
12 kW22 panels12.32 kW606 sq ft (56.3 m²)

Compatible CEC-Listed Inverters for PE-560HGB

Open full string calculator with this panel →
Compatible US-Certified Inverters for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE PE-560HGB
Inverter ModelTopologyAC OutputCEC Eff.Compatibility Check (−10°C)Action
APsystems ELS-3KHybrid3.685 kW94%2–10 panels/string at -10°CVerify Pair
EG4 Electronics IV-8000-HYB-AWHybrid7.863 kW96.5%6–8 panels/string at -10°CVerify Pair
Enphase Energy IQ8X-80-E-USMicroinverter0.384 kW97%1:1 micro pairing (1.46 DC/AC ratio)Verify Pair
Fronius Primo 5.0-1 208-240String5 kW96.5%3–14 panels/string at -10°CVerify Pair
GoodWe GEC5.0-1U-US20Hybrid4.983 kW96%3–9 panels/string at -10°CVerify Pair
GoodWe GW5000-SBP-US20Hybrid4.983 kW96%3–9 panels/string at -10°CVerify Pair

Other Power Classes in This PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Series (11 total CEC variants)

Sibling Power Classes in the PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Series
Series Variant ModelSTC PowerPTC PowerVocIscEfficiency
PE-385HGB385 W356.7 W36.64 V13.47 A19.74%
PE-390HGB390 W361.5 W36.72 V13.59 A20%
PE-395HGB395 W366.2 W36.83 V13.71 A20.26%
PE-400HGB400 W371 W36.94 V13.82 A20.51%
PE-530HGB530 W491.1 W49.43 V13.7 A20.7%
PE-535HGB535 W495.9 W49.51 V13.82 A20.9%
PE-540HGB540 W500.6 W49.68 V13.94 A21.09%
PE-545HGB545 W505.4 W49.76 V13.99 A21.29%
PE-550HGB550 W510.2 W49.82 V14.06 A21.48%
PE-555HGB555 W515 W49.88 V14.12 A21.68%

Engineering FAQ — PREMIER ENERGIES PHOTOVOLTAIC PRIVATE PE-560HGB

How many PREMIER ENERGIES PHOTOVOLTAIC PRIVATE PE-560HGB panels can fit in one 600V string?
At -10°C (14°F) ambient, the PE-560HGB open-circuit voltage rises from 49.91V to 54.89V (using βVoc -0.285%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the PREMIER ENERGIES PHOTOVOLTAIC PRIVATE PE-560HGB?
Rated at 560W STC, the PE-560HGB carries a 519.8W PTC rating (92.8% PTC/STC ratio) and 21.88% module efficiency across 2.56 m² (27.6 sq ft).
Is the PREMIER ENERGIES PHOTOVOLTAIC PRIVATE PE-560HGB listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.

More PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Solar Panels

PE-645G12HGB (645W)PE-555HB (555W)PE-390HB (390W)PE-530HGB (530W)PE-385HGB (385W)PE-670G12HGB (670W)All PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Equipment →