420 W, 108 half-cut cell dual glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
420W / 395.6W
Efficiency
15%
Voc / Vmp
39.04V / 32.43V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | PT IDN SOLAR TECH |
|---|---|
| Model Number (MPN) | IDN108H-420ND |
| Cell Technology | Mono-c-Si · 108 cells |
| Nameplate Power (Pmax STC) | 420 W |
| Real-World Output (PTC) | 395.6 W (94.2% of STC) |
| Module Efficiency | 15% (150 W/m²) |
| Open-Circuit Voltage (Voc) | 39.04 V |
| Maximum Power Voltage (Vmp) | 32.43 V |
| Short-Circuit Current (Isc) | 13.74 A (NEC 1.25× = 17.18 A) |
| Maximum Power Current (Imp) | 12.96 A |
| Temp. Coeff. Power (γPmax) | -0.298 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.24 %/°C |
| Temp. Coeff. Current (αIsc) | +0.041 %/°C |
| Nominal Cell Temp (NOCT) | 43.5 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.8 m² (30.1 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.24%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 39.04 V | 15 | 25 |
| 0°C / 32°F Freezing / Mild Winter | 41.38 V | 14 | 24 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 42.32 V | 14 | 23 |
| -20°C / -4°F Northeast / Midwest Winter | 43.26 V | 13 | 23 |
| -30°C / -22°F Northern Plains / Mountain | 44.19 V | 13 | 22 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.30 kW | 452 sq ft (42.0 m²) |
| 8 kW | 20 panels | 8.40 kW | 603 sq ft (56.0 m²) |
| 10 kW | 24 panels | 10.08 kW | 723 sq ft (67.2 m²) |
| 12 kW | 29 panels | 12.18 kW | 874 sq ft (81.2 m²) |
Compatible CEC-Listed Inverters for IDN108H-420ND
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–14 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-72-2-US | Microinverter | 0.28 kW | 97% | 1:1 micro pairing (1.50 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–18 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
Other Power Classes in This PT IDN SOLAR TECH Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| IDN108H-425ND | 425 W | 400.4 W | 39.24 V | 13.81 A | 15.18% |
| IDN108H-430ND | 430 W | 405.1 W | 39.44 V | 13.88 A | 15.36% |
| IDN108H-435ND | 435 W | 409.9 W | 39.64 V | 13.95 A | 15.54% |
| IDN108H-440ND | 440 W | 414.7 W | 39.84 V | 14.02 A | 15.71% |
| IDN108H-445ND | 445 W | 419.5 W | 40.04 V | 14.09 A | 15.89% |
Engineering FAQ — PT IDN SOLAR TECH IDN108H-420ND
How many PT IDN SOLAR TECH IDN108H-420ND panels can fit in one 600V string?
At -10°C (14°F) ambient, the IDN108H-420ND open-circuit voltage rises from 39.04V to 42.32V (using βVoc -0.24%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the PT IDN SOLAR TECH IDN108H-420ND?
Rated at 420W STC, the IDN108H-420ND carries a 395.6W PTC rating (94.2% PTC/STC ratio) and 15% module efficiency across 2.8 m² (30.1 sq ft).
Is the PT IDN SOLAR TECH IDN108H-420ND listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.