PT IDN SOLAR TECH IDN132H-540ND
540 W, 132 half-cut cell dual glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
540W / 512.7W
Efficiency
22.78%
Voc / Vmp
48.38V / 40.54V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | PT IDN SOLAR TECH |
|---|---|
| Model Number (MPN) | IDN132H-540ND |
| Cell Technology | Mono-c-Si · 132 cells |
| Nameplate Power (Pmax STC) | 540 W |
| Real-World Output (PTC) | 512.7 W (94.9% of STC) |
| Module Efficiency | 22.78% (227.8 W/m²) |
| Open-Circuit Voltage (Voc) | 48.38 V |
| Maximum Power Voltage (Vmp) | 40.54 V |
| Short-Circuit Current (Isc) | 14.08 A (NEC 1.25× = 17.60 A) |
| Maximum Power Current (Imp) | 13.34 A |
| Temp. Coeff. Power (γPmax) | -0.298 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.24 %/°C |
| Temp. Coeff. Current (αIsc) | +0.041 %/°C |
| Nominal Cell Temp (NOCT) | 43.5 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.37 m² (25.5 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.24%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 48.38 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 51.28 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 52.44 V | 11 | 19 |
| -20°C / -4°F Northeast / Midwest Winter | 53.61 V | 11 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 54.77 V | 10 | 18 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 12 panels | 6.48 kW | 306 sq ft (28.4 m²) |
| 8 kW | 15 panels | 8.10 kW | 383 sq ft (35.6 m²) |
| 10 kW | 19 panels | 10.26 kW | 485 sq ft (45.0 m²) |
| 12 kW | 23 panels | 12.42 kW | 587 sq ft (54.5 m²) |
Compatible CEC-Listed Inverters for IDN132H-540ND
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.41 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–15 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This PT IDN SOLAR TECH Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| IDN132H-515ND | 515 W | 488.4 W | 47.39 V | 13.78 A | 21.73% |
| IDN132H-520ND | 520 W | 493.3 W | 47.58 V | 13.84 A | 21.94% |
| IDN132H-525ND | 525 W | 498.1 W | 47.78 V | 13.9 A | 22.15% |
| IDN132H-530ND | 530 W | 503 W | 47.98 V | 13.96 A | 22.36% |
| IDN132H-535ND | 535 W | 507.8 W | 48.18 V | 14.02 A | 22.57% |
Engineering FAQ — PT IDN SOLAR TECH IDN132H-540ND
How many PT IDN SOLAR TECH IDN132H-540ND panels can fit in one 600V string?
At -10°C (14°F) ambient, the IDN132H-540ND open-circuit voltage rises from 48.38V to 52.44V (using βVoc -0.24%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the PT IDN SOLAR TECH IDN132H-540ND?
Rated at 540W STC, the IDN132H-540ND carries a 512.7W PTC rating (94.9% PTC/STC ratio) and 22.78% module efficiency across 2.37 m² (25.5 sq ft).
Is the PT IDN SOLAR TECH IDN132H-540ND listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.