PT. JAYA ELECTRICAL ENERGY JAYAEGN440-108(B)
440 W, 108 half-cut cell dual glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
440W / 417.7W
Efficiency
22.56%
Voc / Vmp
40.24V / 32.17V
Max String (600V)
13 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | PT. JAYA ELECTRICAL ENERGY |
|---|---|
| Model Number (MPN) | JAYAEGN440-108(B) |
| Cell Technology | Mono-c-Si · 108 cells |
| Nameplate Power (Pmax STC) | 440 W |
| Real-World Output (PTC) | 417.7 W (94.9% of STC) |
| Module Efficiency | 22.56% (225.6 W/m²) |
| Open-Circuit Voltage (Voc) | 40.24 V |
| Maximum Power Voltage (Vmp) | 32.17 V |
| Short-Circuit Current (Isc) | 13.98 A (NEC 1.25× = 17.48 A) |
| Maximum Power Current (Imp) | 13.68 A |
| Temp. Coeff. Power (γPmax) | -0.293 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.24 %/°C |
| Temp. Coeff. Current (αIsc) | +0.035 %/°C |
| Nominal Cell Temp (NOCT) | 43.8 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.95 m² (21.0 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.24%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 40.24 V | 14 | 24 |
| 0°C / 32°F Freezing / Mild Winter | 42.65 V | 14 | 23 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 43.62 V | 13 | 22 |
| -20°C / -4°F Northeast / Midwest Winter | 44.59 V | 13 | 22 |
| -30°C / -22°F Northern Plains / Mountain | 45.55 V | 13 | 21 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 14 panels | 6.16 kW | 294 sq ft (27.3 m²) |
| 8 kW | 19 panels | 8.36 kW | 399 sq ft (37.0 m²) |
| 10 kW | 23 panels | 10.12 kW | 483 sq ft (44.9 m²) |
| 12 kW | 28 panels | 12.32 kW | 588 sq ft (54.6 m²) |
Compatible CEC-Listed Inverters for JAYAEGN440-108(B)
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–13 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7PLUS-72-2-US | Microinverter | 0.29 kW | 97% | 1:1 micro pairing (1.52 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 4–18 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
Other Power Classes in This PT. JAYA ELECTRICAL ENERGY Series (5 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| JAYAEGN420-108(B) | 420 W | 398.3 W | 39.66 V | 13.58 A | 21.54% |
| JAYAEGN425-108(B) | 425 W | 403.1 W | 39.81 V | 13.68 A | 21.79% |
| JAYAEGN430-108(B) | 430 W | 408 W | 39.95 V | 13.78 A | 22.05% |
| JAYAEGN435-108(B) | 435 W | 412.8 W | 40.1 V | 13.88 A | 22.31% |
Engineering FAQ — PT. JAYA ELECTRICAL ENERGY JAYAEGN440-108(B)
How many PT. JAYA ELECTRICAL ENERGY JAYAEGN440-108(B) panels can fit in one 600V string?
At -10°C (14°F) ambient, the JAYAEGN440-108(B) open-circuit voltage rises from 40.24V to 43.62V (using βVoc -0.24%/°C), allowing up to 13 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the PT. JAYA ELECTRICAL ENERGY JAYAEGN440-108(B)?
Rated at 440W STC, the JAYAEGN440-108(B) carries a 417.7W PTC rating (94.9% PTC/STC ratio) and 22.56% module efficiency across 1.95 m² (21.0 sq ft).
Is the PT. JAYA ELECTRICAL ENERGY JAYAEGN440-108(B) listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.