435 W, 108 cell monocrystalline module, transparent backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
435W / 412.2W
Efficiency
22.19%
Voc / Vmp
39.17V / 32.11V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | PT LESSO NEW ENERGY |
|---|---|
| Model Number (MPN) | 435C(HWB)54(182) |
| Cell Technology | Mono-c-Si · 108 cells |
| Nameplate Power (Pmax STC) | 435 W |
| Real-World Output (PTC) | 412.2 W (94.8% of STC) |
| Module Efficiency | 22.19% (221.9 W/m²) |
| Open-Circuit Voltage (Voc) | 39.17 V |
| Maximum Power Voltage (Vmp) | 32.11 V |
| Short-Circuit Current (Isc) | 14.79 A (NEC 1.25× = 18.49 A) |
| Maximum Power Current (Imp) | 13.55 A |
| Temp. Coeff. Power (γPmax) | -0.291 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.254 %/°C |
| Temp. Coeff. Current (αIsc) | +0.043 %/°C |
| Nominal Cell Temp (NOCT) | 44.4 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.96 m² (21.1 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.254%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 39.17 V | 15 | 25 |
| 0°C / 32°F Freezing / Mild Winter | 41.66 V | 14 | 24 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 42.65 V | 14 | 23 |
| -20°C / -4°F Northeast / Midwest Winter | 43.65 V | 13 | 22 |
| -30°C / -22°F Northern Plains / Mountain | 44.64 V | 13 | 22 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 14 panels | 6.09 kW | 295 sq ft (27.4 m²) |
| 8 kW | 19 panels | 8.27 kW | 401 sq ft (37.2 m²) |
| 10 kW | 23 panels | 10.01 kW | 485 sq ft (45.1 m²) |
| 12 kW | 28 panels | 12.18 kW | 591 sq ft (54.9 m²) |
Compatible CEC-Listed Inverters for 435C(HWB)54(182)
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–14 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7PLUS-72-2-US | Microinverter | 0.29 kW | 97% | 1:1 micro pairing (1.50 DC/AC ratio) | Verify Pair |
| Fronius Primo GEN24 6.0 208-240 Plus SC | Hybrid | 6.005 kW | 97% | 5–14 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
Engineering FAQ — PT LESSO NEW ENERGY 435C(HWB)54(182)
How many PT LESSO NEW ENERGY 435C(HWB)54(182) panels can fit in one 600V string?
At -10°C (14°F) ambient, the 435C(HWB)54(182) open-circuit voltage rises from 39.17V to 42.65V (using βVoc -0.254%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the PT LESSO NEW ENERGY 435C(HWB)54(182)?
Rated at 435W STC, the 435C(HWB)54(182) carries a 412.2W PTC rating (94.8% PTC/STC ratio) and 22.19% module efficiency across 1.96 m² (21.1 sq ft).
Is the PT LESSO NEW ENERGY 435C(HWB)54(182) listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.