Qcells (Hanwha) Q.PEAK DUO XL-G11.3/BFG 590
590 W, 156 half-cut cell monocrystalline module, bifacial, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
590W / 547.1W
Efficiency
22.18%
Voc / Vmp
53.63V / 45.31V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Qcells (Hanwha) |
|---|---|
| Model Number (MPN) | Q.PEAK DUO XL-G11.3/BFG 590 |
| Cell Technology | Mono-c-Si (Bifacial) · 156 cells |
| Nameplate Power (Pmax STC) | 590 W |
| Real-World Output (PTC) | 547.1 W (92.7% of STC) |
| Module Efficiency | 22.18% (221.8 W/m²) |
| Open-Circuit Voltage (Voc) | 53.63 V |
| Maximum Power Voltage (Vmp) | 45.31 V |
| Short-Circuit Current (Isc) | 13.6 A (NEC 1.25× = 17.00 A) |
| Maximum Power Current (Imp) | 13.02 A |
| Temp. Coeff. Power (γPmax) | -0.362 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.27 %/°C (Class Estimate — Verify Datasheet) |
| Temp. Coeff. Current (αIsc) | +0.041 %/°C |
| Nominal Cell Temp (NOCT) | 46.6 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.66 m² (28.6 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.27%/°C, class estimate) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 53.63 V | 11 | 18 |
| 0°C / 32°F Freezing / Mild Winter | 57.25 V | 10 | 17 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 58.7 V | 10 | 17 |
| -20°C / -4°F Northeast / Midwest Winter | 60.15 V | 9 | 16 |
| -30°C / -22°F Northern Plains / Mountain | 61.59 V | 9 | 16 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 11 panels | 6.49 kW | 315 sq ft (29.3 m²) |
| 8 kW | 14 panels | 8.26 kW | 401 sq ft (37.2 m²) |
| 10 kW | 17 panels | 10.03 kW | 487 sq ft (45.2 m²) |
| 12 kW | 21 panels | 12.39 kW | 601 sq ft (55.9 m²) |
Compatible CEC-Listed Inverters for Q.PEAK DUO XL-G11.3/BFG 590
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.54 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–13 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This Qcells (Hanwha) Series (10 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| Q.PEAK DUO XL-G11.3/BFG 560 | 560 W | 516.6 W | 53.45 V | 13.44 A | 21.05% |
| Q.PEAK DUO XL-G11.3/BFG 565 | 565 W | 521.3 W | 53.48 V | 13.47 A | 21.24% |
| Q.PEAK DUO XL-G11.3/BFG 570 | 570 W | 528 W | 53.5 V | 13.5 A | 21.43% |
| Q.PEAK DUO XL-G11.3/BFG 575 | 575 W | 532.8 W | 53.53 V | 13.52 A | 21.62% |
| Q.PEAK DUO XL-G11.3/BFG 580 | 580 W | 537.5 W | 53.56 V | 13.55 A | 21.8% |
| Q.PEAK DUO XL-G11.3/BFG 585 | 585 W | 542.3 W | 53.59 V | 13.57 A | 21.99% |
| Q.PEAK DUO XL-G11.3/BFG 595 | 595 W | 551.9 W | 53.64 V | 13.62 A | 22.37% |
| Q.PEAK DUO XL-G11.3/BFG 600 | 600 W | 556.7 W | 53.67 V | 13.65 A | 22.56% |
| Q.PEAK DUO XL-G11.3/BFG 605 | 605 W | 559.5 W | 53.7 V | 13.68 A | 22.74% |
Engineering FAQ — Qcells (Hanwha) Q.PEAK DUO XL-G11.3/BFG 590
How many Qcells (Hanwha) Q.PEAK DUO XL-G11.3/BFG 590 panels can fit in one 600V string?
At -10°C (14°F) ambient, the Q.PEAK DUO XL-G11.3/BFG 590 open-circuit voltage rises from 53.63V to 58.7V (using βVoc -0.27%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Qcells (Hanwha) Q.PEAK DUO XL-G11.3/BFG 590?
Rated at 590W STC, the Q.PEAK DUO XL-G11.3/BFG 590 carries a 547.1W PTC rating (92.7% PTC/STC ratio) and 22.18% module efficiency across 2.66 m² (28.6 sq ft).
Is the Qcells (Hanwha) Q.PEAK DUO XL-G11.3/BFG 590 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.