RE CEC-Listed · ResidentialUL 61730Bifacial

RECOM & RCM-440-7BNG

440 W, 108 half-cut cell bifacial monocrystalline module, transparent backhseet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .

STC / PTC Power
440W / 417.3W
Efficiency
22.56%
Voc / Vmp
38.6V / 33V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
RECOM & RCM-440-7BNG — Illustrative category photo — not this exact model · Real bifacial glass-glass solar photovoltaic modules
Illustrative category photo — not this exact model · Real bifacial glass-glass solar photovoltaic modulesWikimedia Commons — File:Agrivoltaics bifacial solar.webp (CC0)
MODULE FOOTPRINT (108 CELLS) 1722mm (67.8") 1134mm (44.6") STC I–V CURVE & COLD VOC (−10°C) −10°C 41.69V Isc 14.3A MPP 440W (33V · 13.36A) Voc 38.6V DC Voltage (V) · Efficiency 22.56%

Electrical & Thermal Specifications (STC)

RECOM & RCM-440-7BNG Electrical and Mechanical Specifications
ManufacturerRECOM &
Model Number (MPN)RCM-440-7BNG
Cell TechnologyMono-c-Si (Bifacial) · 108 cells
Nameplate Power (Pmax STC)440 W
Real-World Output (PTC)417.3 W (94.8% of STC)
Module Efficiency22.56% (225.6 W/m²)
Open-Circuit Voltage (Voc)38.6 V
Maximum Power Voltage (Vmp)33 V
Short-Circuit Current (Isc)14.3 A (NEC 1.25× = 17.88 A)
Maximum Power Current (Imp)13.36 A
Temp. Coeff. Power (γPmax)-0.303 %/°C
Temp. Coeff. Voltage (βVoc)-0.229 %/°C
Temp. Coeff. Current (αIsc)+0.049 %/°C
Nominal Cell Temp (NOCT)43.5 °C
Dimensions (L × W)1722 × 1134 mm (67.8" × 44.6")
Surface Area1.95 m² (21.0 sq ft)
Safety ListingUL 61730

NEC 690.7 Cold-Weather Voc Limits

Computed using this module’s βVoc (-0.229%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.

NEC 690.7 Cold-Weather String Voltage Limits for RCM-440-7BNG
Design Cold TempCold VocMax / 600VMax / 1000V
25°C / 77°F
STC Lab Standard
38.6 V1525
0°C / 32°F
Freezing / Mild Winter
40.81 V1424
-10°C / 14°F
TX / Southeast / Mid-Atlantic
41.69 V1423
-20°C / -4°F
Northeast / Midwest Winter
42.58 V1423
-30°C / -22°F
Northern Plains / Mountain
43.46 V1323

Residential Array Roof Sizing

Residential Roof Footprint Estimates Using RCM-440-7BNG
Target SizePanels NeededActual DCRoof Footprint
6 kW14 panels6.16 kW294 sq ft (27.3 m²)
8 kW19 panels8.36 kW399 sq ft (37.0 m²)
10 kW23 panels10.12 kW483 sq ft (44.9 m²)
12 kW28 panels12.32 kW588 sq ft (54.6 m²)

Compatible CEC-Listed Inverters for RCM-440-7BNG

Open full string calculator with this panel →
Compatible US-Certified Inverters for RECOM & RCM-440-7BNG
Inverter ModelTopologyAC OutputCEC Eff.Compatibility Check (−10°C)Action
APsystems ELS-3KHybrid3.685 kW94%2–14 panels/string at -10°CVerify Pair
EG4 Electronics IV-8000-HYB-AWHybrid7.863 kW96.5%8–11 panels/string at -10°CVerify Pair
Enphase Energy IQ7PLUS-72-2-USMicroinverter0.29 kW97%1:1 micro pairing (1.52 DC/AC ratio)Verify Pair
Fronius Primo 5.0-1 208-240String5 kW96.5%4–19 panels/string at -10°CVerify Pair
GoodWe GEC5.0-1U-US20Hybrid4.983 kW96%4–11 panels/string at -10°CVerify Pair
GoodWe GW5000-SBP-US20Hybrid4.983 kW96%4–11 panels/string at -10°CVerify Pair

Other Power Classes in This RECOM & Series (4 total CEC variants)

Sibling Power Classes in the RECOM & Series
Series Variant ModelSTC PowerPTC PowerVocIscEfficiency
RCM-425-7BNG425 W402.8 W38.3 V14.05 A21.79%
RCM-430-7BNG430 W407.6 W38.4 V14.13 A22.05%
RCM-435-7BNG435 W412.5 W38.5 V14.22 A22.31%

Engineering FAQ — RECOM & RCM-440-7BNG

How many RECOM & RCM-440-7BNG panels can fit in one 600V string?
At -10°C (14°F) ambient, the RCM-440-7BNG open-circuit voltage rises from 38.6V to 41.69V (using βVoc -0.229%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the RECOM & RCM-440-7BNG?
Rated at 440W STC, the RCM-440-7BNG carries a 417.3W PTC rating (94.8% PTC/STC ratio) and 22.56% module efficiency across 1.95 m² (21.0 sq ft).
Is the RECOM & RCM-440-7BNG listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.

More RECOM & Solar Panels

RCM-500-7BMM (500W)RCM-415-7BMG (415W)RCM-395-7BMG (395W)RCM-425-7BNG (425W)RCM-560-7BMF (560W)RCM-530-7BMF (530W)All RECOM & Equipment →