ReCreate DS-MERCURY-485TC
485 W, 120 half-cut cell double glass, white glaze glass, monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
485W / 456.6W
Efficiency
23.1%
Voc / Vmp
42.85V / 35.51V
Max String (600V)
12 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | ReCreate |
|---|---|
| Model Number (MPN) | DS-MERCURY-485TC |
| Cell Technology | Mono-c-Si · 120 cells |
| Nameplate Power (Pmax STC) | 485 W |
| Real-World Output (PTC) | 456.6 W (94.1% of STC) |
| Module Efficiency | 23.1% (231 W/m²) |
| Open-Circuit Voltage (Voc) | 42.85 V |
| Maximum Power Voltage (Vmp) | 35.51 V |
| Short-Circuit Current (Isc) | 14.4 A (NEC 1.25× = 18.00 A) |
| Maximum Power Current (Imp) | 13.66 A |
| Temp. Coeff. Power (γPmax) | -0.275 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.229 %/°C |
| Temp. Coeff. Current (αIsc) | +0.041 %/°C |
| Nominal Cell Temp (NOCT) | 48.3 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.1 m² (22.6 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.229%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 42.85 V | 14 | 23 |
| 0°C / 32°F Freezing / Mild Winter | 45.3 V | 13 | 22 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 46.28 V | 12 | 21 |
| -20°C / -4°F Northeast / Midwest Winter | 47.27 V | 12 | 21 |
| -30°C / -22°F Northern Plains / Mountain | 48.25 V | 12 | 20 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 13 panels | 6.30 kW | 294 sq ft (27.3 m²) |
| 8 kW | 17 panels | 8.24 kW | 384 sq ft (35.7 m²) |
| 10 kW | 21 panels | 10.19 kW | 475 sq ft (44.1 m²) |
| 12 kW | 25 panels | 12.13 kW | 565 sq ft (52.5 m²) |
Compatible CEC-Listed Inverters for DS-MERCURY-485TC
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–12 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–10 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7X-96-2-US | Microinverter | 0.315 kW | 97% | 1:1 micro pairing (1.54 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 4–17 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–10 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–10 panels/string at -10°C | Verify Pair |
Other Power Classes in This ReCreate Series (4 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| DS-MERCURY-470TC | 470 W | 442.1 W | 42.35 V | 14.16 A | 22.38% |
| DS-MERCURY-475TC | 475 W | 446.9 W | 42.51 V | 14.24 A | 22.62% |
| DS-MERCURY-480TC | 480 W | 451.8 W | 42.68 V | 14.32 A | 22.86% |
Engineering FAQ — ReCreate DS-MERCURY-485TC
How many ReCreate DS-MERCURY-485TC panels can fit in one 600V string?
At -10°C (14°F) ambient, the DS-MERCURY-485TC open-circuit voltage rises from 42.85V to 46.28V (using βVoc -0.229%/°C), allowing up to 12 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the ReCreate DS-MERCURY-485TC?
Rated at 485W STC, the DS-MERCURY-485TC carries a 456.6W PTC rating (94.1% PTC/STC ratio) and 23.1% module efficiency across 2.1 m² (22.6 sq ft).
Is the ReCreate DS-MERCURY-485TC listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.