Resun Solar RS8V415M-DG
415 W, 108 cell bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
415W / 390.2W
Efficiency
21.28%
Voc / Vmp
38.15V / 31.71V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Resun Solar |
|---|---|
| Model Number (MPN) | RS8V415M-DG |
| Cell Technology | Mono-c-Si (Bifacial) · 108 cells |
| Nameplate Power (Pmax STC) | 415 W |
| Real-World Output (PTC) | 390.2 W (94% of STC) |
| Module Efficiency | 21.28% (212.8 W/m²) |
| Open-Circuit Voltage (Voc) | 38.15 V |
| Maximum Power Voltage (Vmp) | 31.71 V |
| Short-Circuit Current (Isc) | 13.91 A (NEC 1.25× = 17.39 A) |
| Maximum Power Current (Imp) | 13.09 A |
| Temp. Coeff. Power (γPmax) | -0.303 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.247 %/°C |
| Temp. Coeff. Current (αIsc) | +0.044 %/°C |
| Nominal Cell Temp (NOCT) | 45.9 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.95 m² (21.0 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.247%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 38.15 V | 15 | 26 |
| 0°C / 32°F Freezing / Mild Winter | 40.51 V | 14 | 24 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 41.45 V | 14 | 24 |
| -20°C / -4°F Northeast / Midwest Winter | 42.39 V | 14 | 23 |
| -30°C / -22°F Northern Plains / Mountain | 43.33 V | 13 | 23 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.22 kW | 315 sq ft (29.3 m²) |
| 8 kW | 20 panels | 8.30 kW | 420 sq ft (39.0 m²) |
| 10 kW | 25 panels | 10.38 kW | 525 sq ft (48.8 m²) |
| 12 kW | 29 panels | 12.04 kW | 609 sq ft (56.5 m²) |
Compatible CEC-Listed Inverters for RS8V415M-DG
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–14 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.54 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 4–19 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
Other Power Classes in This Resun Solar Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| RS8V420M-DG | 420 W | 395 W | 38.3 V | 14 A | 21.54% |
| RS8V425M-DG | 425 W | 399.9 W | 38.45 V | 14.09 A | 21.79% |
| RS8V430M-DG | 430 W | 404.7 W | 38.6 V | 14.18 A | 22.05% |
| RS8V435M-DG | 435 W | 409.5 W | 38.75 V | 14.27 A | 22.31% |
| RS8V440M-DG | 440 W | 414.3 W | 38.9 V | 14.36 A | 22.56% |
Engineering FAQ — Resun Solar RS8V415M-DG
How many Resun Solar RS8V415M-DG panels can fit in one 600V string?
At -10°C (14°F) ambient, the RS8V415M-DG open-circuit voltage rises from 38.15V to 41.45V (using βVoc -0.247%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Resun Solar RS8V415M-DG?
Rated at 415W STC, the RS8V415M-DG carries a 390.2W PTC rating (94% PTC/STC ratio) and 21.28% module efficiency across 1.95 m² (21.0 sq ft).
Is the Resun Solar RS8V415M-DG listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.