RNG International RSP445D-120
445 W, 120 cell monocrystalline module, white backsheet, silver frame, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
445W / 419.7W
Efficiency
20.7%
Voc / Vmp
41.1V / 34.48V
Max String (600V)
13 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | RNG International |
|---|---|
| Model Number (MPN) | RSP445D-120 |
| Cell Technology | Mono-c-Si · 120 cells |
| Nameplate Power (Pmax STC) | 445 W |
| Real-World Output (PTC) | 419.7 W (94.3% of STC) |
| Module Efficiency | 20.7% (207 W/m²) |
| Open-Circuit Voltage (Voc) | 41.1 V |
| Maximum Power Voltage (Vmp) | 34.48 V |
| Short-Circuit Current (Isc) | 13.82 A (NEC 1.25× = 17.27 A) |
| Maximum Power Current (Imp) | 12.91 A |
| Temp. Coeff. Power (γPmax) | -0.328 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.289 %/°C |
| Temp. Coeff. Current (αIsc) | +0.035 %/°C |
| Nominal Cell Temp (NOCT) | 43.2 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.15 m² (23.1 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.289%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 41.1 V | 14 | 24 |
| 0°C / 32°F Freezing / Mild Winter | 44.07 V | 13 | 22 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 45.26 V | 13 | 22 |
| -20°C / -4°F Northeast / Midwest Winter | 46.45 V | 12 | 21 |
| -30°C / -22°F Northern Plains / Mountain | 47.63 V | 12 | 20 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 14 panels | 6.23 kW | 324 sq ft (30.1 m²) |
| 8 kW | 18 panels | 8.01 kW | 417 sq ft (38.7 m²) |
| 10 kW | 23 panels | 10.23 kW | 532 sq ft (49.4 m²) |
| 12 kW | 27 panels | 12.02 kW | 625 sq ft (58.0 m²) |
Compatible CEC-Listed Inverters for RSP445D-120
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–13 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–10 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7PLUS-72-2-US | Microinverter | 0.29 kW | 97% | 1:1 micro pairing (1.53 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 4–17 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–10 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–10 panels/string at -10°C | Verify Pair |
Other Power Classes in This RNG International Series (5 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| RSP450D-120 | 450 W | 424.5 W | 41.25 V | 13.89 A | 20.93% |
| RSP455D-120 | 455 W | 429.3 W | 41.4 V | 13.97 A | 21.16% |
| RSP460D-120 | 460 W | 434.2 W | 41.58 V | 14.07 A | 21.4% |
| RSP465D-120 | 465 W | 439 W | 41.71 V | 14.15 A | 21.63% |
Engineering FAQ — RNG International RSP445D-120
How many RNG International RSP445D-120 panels can fit in one 600V string?
At -10°C (14°F) ambient, the RSP445D-120 open-circuit voltage rises from 41.1V to 45.26V (using βVoc -0.289%/°C), allowing up to 13 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the RNG International RSP445D-120?
Rated at 445W STC, the RSP445D-120 carries a 419.7W PTC rating (94.3% PTC/STC ratio) and 20.7% module efficiency across 2.15 m² (23.1 sq ft).
Is the RNG International RSP445D-120 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.