Runergy HY-DH144N8B-545
545 W, 144 cell monocrystalline module, black backsheet, black frame, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
545W / 511.3W
Efficiency
21.12%
Voc / Vmp
50.07V / 41.39V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Runergy |
|---|---|
| Model Number (MPN) | HY-DH144N8B-545 |
| Cell Technology | Mono-c-Si · 144 cells |
| Nameplate Power (Pmax STC) | 545 W |
| Real-World Output (PTC) | 511.3 W (93.8% of STC) |
| Module Efficiency | 21.12% (211.2 W/m²) |
| Open-Circuit Voltage (Voc) | 50.07 V |
| Maximum Power Voltage (Vmp) | 41.39 V |
| Short-Circuit Current (Isc) | 13.95 A (NEC 1.25× = 17.44 A) |
| Maximum Power Current (Imp) | 13.17 A |
| Temp. Coeff. Power (γPmax) | -0.357 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.245 %/°C |
| Temp. Coeff. Current (αIsc) | +0.037 %/°C |
| Nominal Cell Temp (NOCT) | 43.3 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.58 m² (27.8 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.245%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 50.07 V | 11 | 19 |
| 0°C / 32°F Freezing / Mild Winter | 53.14 V | 11 | 18 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 54.36 V | 11 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 55.59 V | 10 | 17 |
| -30°C / -22°F Northern Plains / Mountain | 56.82 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 12 panels | 6.54 kW | 333 sq ft (31.0 m²) |
| 8 kW | 15 panels | 8.18 kW | 417 sq ft (38.7 m²) |
| 10 kW | 19 panels | 10.36 kW | 528 sq ft (49.0 m²) |
| 12 kW | 23 panels | 12.54 kW | 639 sq ft (59.3 m²) |
Compatible CEC-Listed Inverters for HY-DH144N8B-545
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.42 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This Runergy Series (13 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| HY-DH144N8B-550 | 550 W | 516.2 W | 50.27 V | 14.01 A | 21.32% |
| HY-DH144N8B-555 | 555 W | 521 W | 50.47 V | 14.07 A | 21.51% |
| HY-DH144N8B-560 | 560 W | 525.8 W | 50.67 V | 14.13 A | 21.71% |
| HY-DH144N8B-565 | 565 W | 530.6 W | 50.87 V | 14.19 A | 21.9% |
| HY-DH144N8B-570 | 570 W | 535.4 W | 51.07 V | 14.25 A | 22.09% |
| HY-DH144N8B-575 | 575 W | 540.3 W | 51.27 V | 14.31 A | 22.29% |
| HY-DH144N8B-580 | 580 W | 545.1 W | 51.47 V | 14.37 A | 22.48% |
| HY-DH144N8B-585 | 585 W | 549.9 W | 51.67 V | 14.43 A | 22.67% |
| HY-DH144N8B-590 | 590 W | 561 W | 52.37 V | 13.89 A | 22.87% |
| HY-DH144N8B-595 | 595 W | 565.8 W | 52.58 V | 13.93 A | 23.06% |
| HY-DH144N8B-600 | 600 W | 570.7 W | 52.79 V | 13.97 A | 23.26% |
| HY-DH144N8B-605 | 605 W | 575.6 W | 53.5 V | 14.16 A | 23.45% |
Engineering FAQ — Runergy HY-DH144N8B-545
How many Runergy HY-DH144N8B-545 panels can fit in one 600V string?
At -10°C (14°F) ambient, the HY-DH144N8B-545 open-circuit voltage rises from 50.07V to 54.36V (using βVoc -0.245%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Runergy HY-DH144N8B-545?
Rated at 545W STC, the HY-DH144N8B-545 carries a 511.3W PTC rating (93.8% PTC/STC ratio) and 21.12% module efficiency across 2.58 m² (27.8 sq ft).
Is the Runergy HY-DH144N8B-545 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.