Runergy HY-DH96N11-425
425 W, 96 half-cut cell dual glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
425W / 402.5W
Efficiency
21.25%
Voc / Vmp
34.56V / 28.74V
Max String (600V)
16 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Runergy |
|---|---|
| Model Number (MPN) | HY-DH96N11-425 |
| Cell Technology | Mono-c-Si · 96 cells |
| Nameplate Power (Pmax STC) | 425 W |
| Real-World Output (PTC) | 402.5 W (94.7% of STC) |
| Module Efficiency | 21.25% (212.5 W/m²) |
| Open-Circuit Voltage (Voc) | 34.56 V |
| Maximum Power Voltage (Vmp) | 28.74 V |
| Short-Circuit Current (Isc) | 15.67 A (NEC 1.25× = 19.59 A) |
| Maximum Power Current (Imp) | 14.79 A |
| Temp. Coeff. Power (γPmax) | -0.31 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.235 %/°C |
| Temp. Coeff. Current (αIsc) | +0.033 %/°C |
| Nominal Cell Temp (NOCT) | 43.1 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2 m² (21.5 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.235%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 34.56 V | 17 | 28 |
| 0°C / 32°F Freezing / Mild Winter | 36.59 V | 16 | 27 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 37.4 V | 16 | 26 |
| -20°C / -4°F Northeast / Midwest Winter | 38.21 V | 15 | 26 |
| -30°C / -22°F Northern Plains / Mountain | 39.03 V | 15 | 25 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.38 kW | 323 sq ft (30.0 m²) |
| 8 kW | 19 panels | 8.07 kW | 409 sq ft (38.0 m²) |
| 10 kW | 24 panels | 10.20 kW | 517 sq ft (48.0 m²) |
| 12 kW | 29 panels | 12.32 kW | 624 sq ft (58.0 m²) |
Compatible CEC-Listed Inverters for HY-DH96N11-425
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 3–16 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 9–12 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-72-2-US | Microinverter | 0.28 kW | 97% | 1:1 micro pairing (1.52 DC/AC ratio) | Verify Pair |
| Fronius Primo GEN24 6.0 208-240 Plus SC | Hybrid | 6.005 kW | 97% | 5–16 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 5–13 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 5–13 panels/string at -10°C | Verify Pair |
Other Power Classes in This Runergy Series (9 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| HY-DH96N11-430 | 430 W | 407.4 W | 34.7 V | 15.75 A | 21.5% |
| HY-DH96N11-435 | 435 W | 412.2 W | 34.84 V | 15.83 A | 21.75% |
| HY-DH96N11-440 | 440 W | 417 W | 34.98 V | 15.91 A | 22% |
| HY-DH96N11-445 | 445 W | 421.9 W | 35.12 V | 15.99 A | 22.25% |
| HY-DH96N11-450 | 450 W | 426.7 W | 35.26 V | 16.07 A | 22.5% |
| HY-DH96N11-455 | 455 W | 431.6 W | 35.39 V | 16.15 A | 22.75% |
| HY-DH96N11-460 | 460 W | 436.5 W | 35.52 V | 16.23 A | 23% |
| HY-DH96N11-465 | 465 W | 441.3 W | 35.65 V | 16.31 A | 23.25% |
Engineering FAQ — Runergy HY-DH96N11-425
How many Runergy HY-DH96N11-425 panels can fit in one 600V string?
At -10°C (14°F) ambient, the HY-DH96N11-425 open-circuit voltage rises from 34.56V to 37.4V (using βVoc -0.235%/°C), allowing up to 16 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Runergy HY-DH96N11-425?
Rated at 425W STC, the HY-DH96N11-425 carries a 402.5W PTC rating (94.7% PTC/STC ratio) and 21.25% module efficiency across 2 m² (21.5 sq ft).
Is the Runergy HY-DH96N11-425 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.