Saatvik Green Energy (P) SGE440-120MBHC
440 W, 120 half-cut cell monocrystalline module, bifacial, transparent backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
440W / 408.3W
Efficiency
20.47%
Voc / Vmp
40.72V / 33.93V
Max String (600V)
13 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Saatvik Green Energy (P) |
|---|---|
| Model Number (MPN) | SGE440-120MBHC |
| Cell Technology | Mono-c-Si (Bifacial) · 120 cells |
| Nameplate Power (Pmax STC) | 440 W |
| Real-World Output (PTC) | 408.3 W (92.8% of STC) |
| Module Efficiency | 20.47% (204.7 W/m²) |
| Open-Circuit Voltage (Voc) | 40.72 V |
| Maximum Power Voltage (Vmp) | 33.93 V |
| Short-Circuit Current (Isc) | 13.62 A (NEC 1.25× = 17.02 A) |
| Maximum Power Current (Imp) | 12.97 A |
| Temp. Coeff. Power (γPmax) | -0.367 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.282 %/°C |
| Temp. Coeff. Current (αIsc) | +0.047 %/°C |
| Nominal Cell Temp (NOCT) | 45.5 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.15 m² (23.1 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.282%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 40.72 V | 14 | 24 |
| 0°C / 32°F Freezing / Mild Winter | 43.59 V | 13 | 22 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 44.74 V | 13 | 22 |
| -20°C / -4°F Northeast / Midwest Winter | 45.89 V | 13 | 21 |
| -30°C / -22°F Northern Plains / Mountain | 47.04 V | 12 | 21 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 14 panels | 6.16 kW | 324 sq ft (30.1 m²) |
| 8 kW | 19 panels | 8.36 kW | 440 sq ft (40.9 m²) |
| 10 kW | 23 panels | 10.12 kW | 532 sq ft (49.4 m²) |
| 12 kW | 28 panels | 12.32 kW | 648 sq ft (60.2 m²) |
Compatible CEC-Listed Inverters for SGE440-120MBHC
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–13 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–10 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7PLUS-72-2-US | Microinverter | 0.29 kW | 97% | 1:1 micro pairing (1.52 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–17 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
Other Power Classes in This Saatvik Green Energy (P) Series (2 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| SGE445-120MBHC | 445 W | 413.1 W | 40.93 V | 13.7 A | 20.7% |
Engineering FAQ — Saatvik Green Energy (P) SGE440-120MBHC
How many Saatvik Green Energy (P) SGE440-120MBHC panels can fit in one 600V string?
At -10°C (14°F) ambient, the SGE440-120MBHC open-circuit voltage rises from 40.72V to 44.74V (using βVoc -0.282%/°C), allowing up to 13 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Saatvik Green Energy (P) SGE440-120MBHC?
Rated at 440W STC, the SGE440-120MBHC carries a 408.3W PTC rating (92.8% PTC/STC ratio) and 20.47% module efficiency across 2.15 m² (23.1 sq ft).
Is the Saatvik Green Energy (P) SGE440-120MBHC listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.