SEG Solar SEG-585-BMZ-BG
585 W, 156 half-cut cells double glass bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
585W / 548.9W
Efficiency
21.12%
Voc / Vmp
53.2V / 44.56V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | SEG Solar |
|---|---|
| Model Number (MPN) | SEG-585-BMZ-BG |
| Cell Technology | Mono-c-Si (Bifacial) · 156 cells |
| Nameplate Power (Pmax STC) | 585 W |
| Real-World Output (PTC) | 548.9 W (93.8% of STC) |
| Module Efficiency | 21.12% (211.2 W/m²) |
| Open-Circuit Voltage (Voc) | 53.2 V |
| Maximum Power Voltage (Vmp) | 44.56 V |
| Short-Circuit Current (Isc) | 13.88 A (NEC 1.25× = 17.35 A) |
| Maximum Power Current (Imp) | 13.13 A |
| Temp. Coeff. Power (γPmax) | -0.351 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.247 %/°C |
| Temp. Coeff. Current (αIsc) | +0.035 %/°C |
| Nominal Cell Temp (NOCT) | 43.6 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.77 m² (29.8 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.247%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 53.2 V | 11 | 18 |
| 0°C / 32°F Freezing / Mild Winter | 56.49 V | 10 | 17 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 57.8 V | 10 | 17 |
| -20°C / -4°F Northeast / Midwest Winter | 59.11 V | 10 | 16 |
| -30°C / -22°F Northern Plains / Mountain | 60.43 V | 9 | 16 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 11 panels | 6.43 kW | 328 sq ft (30.5 m²) |
| 8 kW | 14 panels | 8.19 kW | 417 sq ft (38.8 m²) |
| 10 kW | 18 panels | 10.53 kW | 537 sq ft (49.9 m²) |
| 12 kW | 21 panels | 12.29 kW | 626 sq ft (58.2 m²) |
Compatible CEC-Listed Inverters for SEG-585-BMZ-BG
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.52 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–13 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This SEG Solar Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| SEG-590-BMZ-BG | 590 W | 553.8 W | 53.3 V | 13.93 A | 21.3% |
| SEG-595-BMZ-BG | 595 W | 558.6 W | 53.4 V | 13.98 A | 21.48% |
| SEG-600-BMZ-BG | 600 W | 563.4 W | 53.5 V | 14.03 A | 21.66% |
| SEG-605-BMZ-BG | 605 W | 568.2 W | 53.61 V | 14.08 A | 21.84% |
| SEG-610-BMZ-BG | 610 W | 573 W | 53.7 V | 14.13 A | 22.02% |
Engineering FAQ — SEG Solar SEG-585-BMZ-BG
How many SEG Solar SEG-585-BMZ-BG panels can fit in one 600V string?
At -10°C (14°F) ambient, the SEG-585-BMZ-BG open-circuit voltage rises from 53.2V to 57.8V (using βVoc -0.247%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the SEG Solar SEG-585-BMZ-BG?
Rated at 585W STC, the SEG-585-BMZ-BG carries a 548.9W PTC rating (93.8% PTC/STC ratio) and 21.12% module efficiency across 2.77 m² (29.8 sq ft).
Is the SEG Solar SEG-585-BMZ-BG listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.