Shanghai Aerospace Automobile Electromechanical HT78-18X-600
600 W, 144 half-cut cell monocrystalline module, black or white backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
600W / 565.1W
Efficiency
22.06%
Voc / Vmp
54.09V / 45.58V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Shanghai Aerospace Automobile Electromechanical |
|---|---|
| Model Number (MPN) | HT78-18X-600 |
| Cell Technology | Mono-c-Si · 156 cells |
| Nameplate Power (Pmax STC) | 600 W |
| Real-World Output (PTC) | 565.1 W (94.2% of STC) |
| Module Efficiency | 22.06% (220.6 W/m²) |
| Open-Circuit Voltage (Voc) | 54.09 V |
| Maximum Power Voltage (Vmp) | 45.58 V |
| Short-Circuit Current (Isc) | 14.1 A (NEC 1.25× = 17.63 A) |
| Maximum Power Current (Imp) | 13.17 A |
| Temp. Coeff. Power (γPmax) | -0.337 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.271 %/°C |
| Temp. Coeff. Current (αIsc) | +0.044 %/°C |
| Nominal Cell Temp (NOCT) | 43.6 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.72 m² (29.3 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.271%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 54.09 V | 11 | 18 |
| 0°C / 32°F Freezing / Mild Winter | 57.75 V | 10 | 17 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 59.22 V | 10 | 16 |
| -20°C / -4°F Northeast / Midwest Winter | 60.69 V | 9 | 16 |
| -30°C / -22°F Northern Plains / Mountain | 62.15 V | 9 | 16 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 10 panels | 6.00 kW | 293 sq ft (27.2 m²) |
| 8 kW | 14 panels | 8.40 kW | 410 sq ft (38.1 m²) |
| 10 kW | 17 panels | 10.20 kW | 498 sq ft (46.2 m²) |
| 12 kW | 20 panels | 12.00 kW | 586 sq ft (54.4 m²) |
Compatible CEC-Listed Inverters for HT78-18X-600
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–13 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This Shanghai Aerospace Automobile Electromechanical Series (7 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| HT78-18X-570 | 570 W | 527.4 W | 53.19 V | 13.68 A | 20.37% |
| HT78-18X-575 | 575 W | 532.1 W | 53.34 V | 13.75 A | 20.55% |
| HT78-18X-580 | 580 W | 536.9 W | 53.49 V | 13.82 A | 20.73% |
| HT78-18X-585 | 585 W | 541.7 W | 53.64 V | 13.89 A | 20.9% |
| HT78-18X-590 | 590 W | 546.4 W | 53.79 V | 13.96 A | 21.08% |
| HT78-18X-595 | 595 W | 551.2 W | 53.94 V | 14.03 A | 21.26% |
Engineering FAQ — Shanghai Aerospace Automobile Electromechanical HT78-18X-600
How many Shanghai Aerospace Automobile Electromechanical HT78-18X-600 panels can fit in one 600V string?
At -10°C (14°F) ambient, the HT78-18X-600 open-circuit voltage rises from 54.09V to 59.22V (using βVoc -0.271%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Shanghai Aerospace Automobile Electromechanical HT78-18X-600?
Rated at 600W STC, the HT78-18X-600 carries a 565.1W PTC rating (94.2% PTC/STC ratio) and 22.06% module efficiency across 2.72 m² (29.3 sq ft).
Is the Shanghai Aerospace Automobile Electromechanical HT78-18X-600 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.