Shanghai ST Solar STM350-130
350 W Monocrystalline Module. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
350W / 312.9W
Efficiency
15.43%
Voc / Vmp
81.25V / 65V
Max String (600V)
6 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | Shanghai ST Solar |
|---|---|
| Model Number (MPN) | STM350-130 |
| Cell Technology | Mono-c-Si · 130 cells |
| Nameplate Power (Pmax STC) | 350 W |
| Real-World Output (PTC) | 312.9 W (89.4% of STC) |
| Module Efficiency | 15.43% (154.3 W/m²) |
| Open-Circuit Voltage (Voc) | 81.25 V |
| Maximum Power Voltage (Vmp) | 65 V |
| Short-Circuit Current (Isc) | 5.98 A (NEC 1.25× = 7.48 A) |
| Maximum Power Current (Imp) | 5.38 A |
| Temp. Coeff. Power (γPmax) | -0.46 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.34 %/°C |
| Temp. Coeff. Current (αIsc) | +0.05 %/°C |
| Nominal Cell Temp (NOCT) | 47.1 °C |
| Dimensions (L × W) | 1715 × 1323 mm (67.5" × 52.1") |
| Surface Area | 2.269 m² (24.4 sq ft) |
| Safety Listing | UL 1703 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.34%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 81.25 V | 7 | 12 |
| 0°C / 32°F Freezing / Mild Winter | 88.16 V | 6 | 11 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 90.92 V | 6 | 10 |
| -20°C / -4°F Northeast / Midwest Winter | 93.68 V | 6 | 10 |
| -30°C / -22°F Northern Plains / Mountain | 96.44 V | 6 | 10 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 18 panels | 6.30 kW | 440 sq ft (40.8 m²) |
| 8 kW | 23 panels | 8.05 kW | 562 sq ft (52.2 m²) |
| 10 kW | 29 panels | 10.15 kW | 708 sq ft (65.8 m²) |
| 12 kW | 35 panels | 12.25 kW | 855 sq ft (79.4 m²) |
CEC-Listed US Equivalents to Shanghai ST Solar STM350-130
Looking to build a compliant US residential system with comparable wattage (350W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
Compatible CEC-Listed Inverters for STM350-130
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 1–6 panels/string at -10°C | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 2–8 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 3–5 panels/string at -10°C | Verify Pair |
| Growatt SPH 3000TL BL-US | Hybrid | 2.934 kW | 93.5% | 3–5 panels/string at -10°C | Verify Pair |
| Growatt MIN 3000TL-XH-US | Hybrid | 3.095 kW | 97% | 3–5 panels/string at -10°C | Verify Pair |
Other Power Classes in This Shanghai ST Solar Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| STM325-130 | 325 W | 289.9 W | 81.25 V | 5.56 A | 14.32% |
| STM330-130 | 330 W | 294.5 W | 81.25 V | 5.64 A | 14.54% |
| STM335-130 | 335 W | 299.1 W | 81.25 V | 5.73 A | 14.76% |
| STM340-130 | 340 W | 303.7 W | 81.25 V | 5.81 A | 14.98% |
| STM345-130 | 345 W | 308.3 W | 81.25 V | 5.9 A | 15.21% |
Engineering FAQ — Shanghai ST Solar STM350-130
How many Shanghai ST Solar STM350-130 panels can fit in one 600V string?
At -10°C (14°F) ambient, the STM350-130 open-circuit voltage rises from 81.25V to 90.92V (using βVoc -0.34%/°C), allowing up to 6 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Shanghai ST Solar STM350-130?
Rated at 350W STC, the STM350-130 carries a 312.9W PTC rating (89.4% PTC/STC ratio) and 15.43% module efficiency across 2.269 m² (24.4 sq ft).
Is the Shanghai ST Solar STM350-130 listed in the CEC registry for US residential designs?
No — this model is categorized as Legacy / Replacement Reference (UL 1703). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.