Silfab Solar SIL-515XM
515 W, 132 half-cut cells bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
515W / 481.8W
Efficiency
22.39%
Voc / Vmp
47.41V / 40.19V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Silfab Solar |
|---|---|
| Model Number (MPN) | SIL-515XM |
| Cell Technology | Mono-c-Si (Bifacial) · 132 cells |
| Nameplate Power (Pmax STC) | 515 W |
| Real-World Output (PTC) | 481.8 W (93.6% of STC) |
| Module Efficiency | 22.39% (223.9 W/m²) |
| Open-Circuit Voltage (Voc) | 47.41 V |
| Maximum Power Voltage (Vmp) | 40.19 V |
| Short-Circuit Current (Isc) | 13.61 A (NEC 1.25× = 17.01 A) |
| Maximum Power Current (Imp) | 12.81 A |
| Temp. Coeff. Power (γPmax) | -0.294 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.262 %/°C |
| Temp. Coeff. Current (αIsc) | +0.05 %/°C |
| Nominal Cell Temp (NOCT) | 48.7 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.3 m² (24.8 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.262%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 47.41 V | 12 | 21 |
| 0°C / 32°F Freezing / Mild Winter | 50.52 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 51.76 V | 11 | 19 |
| -20°C / -4°F Northeast / Midwest Winter | 53 V | 11 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 54.24 V | 11 | 18 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 12 panels | 6.18 kW | 297 sq ft (27.6 m²) |
| 8 kW | 16 panels | 8.24 kW | 396 sq ft (36.8 m²) |
| 10 kW | 20 panels | 10.30 kW | 495 sq ft (46.0 m²) |
| 12 kW | 24 panels | 12.36 kW | 594 sq ft (55.2 m²) |
Compatible CEC-Listed Inverters for SIL-515XM
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.34 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–15 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This Silfab Solar Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| SIL-520XM | 520 W | 486.6 W | 47.52 V | 13.65 A | 22.61% |
| SIL-525XM | 525 W | 491.4 W | 47.63 V | 13.68 A | 22.83% |
| SIL-530XM | 530 W | 496.2 W | 47.74 V | 13.71 A | 23.04% |
| SIL-535XM | 535 W | 501 W | 47.85 V | 13.74 A | 23.26% |
| SIL-540XM | 540 W | 505.8 W | 47.95 V | 13.78 A | 23.48% |
Engineering FAQ — Silfab Solar SIL-515XM
How many Silfab Solar SIL-515XM panels can fit in one 600V string?
At -10°C (14°F) ambient, the SIL-515XM open-circuit voltage rises from 47.41V to 51.76V (using βVoc -0.262%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Silfab Solar SIL-515XM?
Rated at 515W STC, the SIL-515XM carries a 481.8W PTC rating (93.6% PTC/STC ratio) and 22.39% module efficiency across 2.3 m² (24.8 sq ft).
Is the Silfab Solar SIL-515XM listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.