SOLAR LONG PV-TECH(CAMBODIA) SL415ML-54H-VTL
415 W, 108 half-cut cell monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
415W / 388.2W
Efficiency
21.39%
Voc / Vmp
37.31V / 30.79V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | SOLAR LONG PV-TECH(CAMBODIA) |
|---|---|
| Model Number (MPN) | SL415ML-54H-VTL |
| Cell Technology | Mono-c-Si · 108 cells |
| Nameplate Power (Pmax STC) | 415 W |
| Real-World Output (PTC) | 388.2 W (93.5% of STC) |
| Module Efficiency | 21.39% (213.9 W/m²) |
| Open-Circuit Voltage (Voc) | 37.31 V |
| Maximum Power Voltage (Vmp) | 30.79 V |
| Short-Circuit Current (Isc) | 14.01 A (NEC 1.25× = 17.51 A) |
| Maximum Power Current (Imp) | 13.48 A |
| Temp. Coeff. Power (γPmax) | -0.341 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.272 %/°C |
| Temp. Coeff. Current (αIsc) | +0.043 %/°C |
| Nominal Cell Temp (NOCT) | 45.1 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.94 m² (20.9 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.272%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 37.31 V | 16 | 26 |
| 0°C / 32°F Freezing / Mild Winter | 39.85 V | 15 | 25 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 40.86 V | 14 | 24 |
| -20°C / -4°F Northeast / Midwest Winter | 41.88 V | 14 | 23 |
| -30°C / -22°F Northern Plains / Mountain | 42.89 V | 13 | 23 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.22 kW | 313 sq ft (29.1 m²) |
| 8 kW | 20 panels | 8.30 kW | 418 sq ft (38.8 m²) |
| 10 kW | 25 panels | 10.38 kW | 522 sq ft (48.5 m²) |
| 12 kW | 29 panels | 12.04 kW | 606 sq ft (56.3 m²) |
Compatible CEC-Listed Inverters for SL415ML-54H-VTL
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–14 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.54 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 4–19 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–12 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–12 panels/string at -10°C | Verify Pair |
Other Power Classes in This SOLAR LONG PV-TECH(CAMBODIA) Series (5 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| SL395ML-54H-VTL | 395 W | 369 W | 36.9 V | 13.71 A | 20.36% |
| SL400ML-54H-VTL | 400 W | 373.8 W | 36.98 V | 13.78 A | 20.62% |
| SL405ML-54H-VTL | 405 W | 378.6 W | 37.06 V | 13.85 A | 20.88% |
| SL410ML-54H-VTL | 410 W | 383.4 W | 37.14 V | 13.92 A | 21.13% |
Engineering FAQ — SOLAR LONG PV-TECH(CAMBODIA) SL415ML-54H-VTL
How many SOLAR LONG PV-TECH(CAMBODIA) SL415ML-54H-VTL panels can fit in one 600V string?
At -10°C (14°F) ambient, the SL415ML-54H-VTL open-circuit voltage rises from 37.31V to 40.86V (using βVoc -0.272%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the SOLAR LONG PV-TECH(CAMBODIA) SL415ML-54H-VTL?
Rated at 415W STC, the SL415ML-54H-VTL carries a 388.2W PTC rating (93.5% PTC/STC ratio) and 21.39% module efficiency across 1.94 m² (20.9 sq ft).
Is the SOLAR LONG PV-TECH(CAMBODIA) SL415ML-54H-VTL listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.