SOLEX ENERGY SMFB54HM10-390
390 W, 108 half-cut cell monocrystalline module, black backsheet, black frame, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
390W / 363.8W
Efficiency
20%
Voc / Vmp
38.23V / 31.13V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | SOLEX ENERGY |
|---|---|
| Model Number (MPN) | SMFB54HM10-390 |
| Cell Technology | Mono-c-Si · 108 cells |
| Nameplate Power (Pmax STC) | 390 W |
| Real-World Output (PTC) | 363.8 W (93.3% of STC) |
| Module Efficiency | 20% (200 W/m²) |
| Open-Circuit Voltage (Voc) | 38.23 V |
| Maximum Power Voltage (Vmp) | 31.13 V |
| Short-Circuit Current (Isc) | 13.15 A (NEC 1.25× = 16.44 A) |
| Maximum Power Current (Imp) | 12.54 A |
| Temp. Coeff. Power (γPmax) | -0.311 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.229 %/°C |
| Temp. Coeff. Current (αIsc) | +0.013 %/°C |
| Nominal Cell Temp (NOCT) | 47.3 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.95 m² (21.0 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.229%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 38.23 V | 15 | 26 |
| 0°C / 32°F Freezing / Mild Winter | 40.42 V | 14 | 24 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 41.29 V | 14 | 24 |
| -20°C / -4°F Northeast / Midwest Winter | 42.17 V | 14 | 23 |
| -30°C / -22°F Northern Plains / Mountain | 43.05 V | 13 | 23 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 16 panels | 6.24 kW | 336 sq ft (31.2 m²) |
| 8 kW | 21 panels | 8.19 kW | 441 sq ft (40.9 m²) |
| 10 kW | 26 panels | 10.14 kW | 546 sq ft (50.7 m²) |
| 12 kW | 31 panels | 12.09 kW | 651 sq ft (60.4 m²) |
Compatible CEC-Listed Inverters for SMFB54HM10-390
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–14 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.44 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–19 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
Other Power Classes in This SOLEX ENERGY Series (7 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| SMFB54HM10-395 | 395 W | 368.6 W | 38.4 V | 13.24 A | 20.26% |
| SMFB54HM10-400 | 400 W | 373.4 W | 38.57 V | 13.33 A | 20.51% |
| SMFB54HM10-405 | 405 W | 378.2 W | 38.74 V | 13.42 A | 20.77% |
| SMFB54HM10-410 | 410 W | 383 W | 38.99 V | 13.5 A | 21.03% |
| SMFB54HM10-415 | 415 W | 387.8 W | 39.16 V | 13.58 A | 21.28% |
| SMFB54HM10-420 | 420 W | 392.6 W | 39.31 V | 13.66 A | 21.54% |
Engineering FAQ — SOLEX ENERGY SMFB54HM10-390
How many SOLEX ENERGY SMFB54HM10-390 panels can fit in one 600V string?
At -10°C (14°F) ambient, the SMFB54HM10-390 open-circuit voltage rises from 38.23V to 41.29V (using βVoc -0.229%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the SOLEX ENERGY SMFB54HM10-390?
Rated at 390W STC, the SMFB54HM10-390 carries a 363.8W PTC rating (93.3% PTC/STC ratio) and 20% module efficiency across 1.95 m² (21.0 sq ft).
Is the SOLEX ENERGY SMFB54HM10-390 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.