Talesun Solar TP7G54M(H)-395
395 W, 108 half-cut cell bifacial monocrystalline module, transparent backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
395W / 366.3W
Efficiency
20.24%
Voc / Vmp
36.75V / 30.85V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Talesun Solar |
|---|---|
| Model Number (MPN) | TP7G54M(H)-395 |
| Cell Technology | Mono-c-Si (Bifacial) · 108 cells |
| Nameplate Power (Pmax STC) | 395 W |
| Real-World Output (PTC) | 366.3 W (92.7% of STC) |
| Module Efficiency | 20.24% (202.4 W/m²) |
| Open-Circuit Voltage (Voc) | 36.75 V |
| Maximum Power Voltage (Vmp) | 30.85 V |
| Short-Circuit Current (Isc) | 13.69 A (NEC 1.25× = 17.11 A) |
| Maximum Power Current (Imp) | 12.81 A |
| Temp. Coeff. Power (γPmax) | -0.402 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.304 %/°C |
| Temp. Coeff. Current (αIsc) | +0.045 %/°C |
| Nominal Cell Temp (NOCT) | 43.8 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.952 m² (21.0 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.304%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 36.75 V | 16 | 27 |
| 0°C / 32°F Freezing / Mild Winter | 39.54 V | 15 | 25 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 40.66 V | 14 | 24 |
| -20°C / -4°F Northeast / Midwest Winter | 41.78 V | 14 | 23 |
| -30°C / -22°F Northern Plains / Mountain | 42.89 V | 13 | 23 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 16 panels | 6.32 kW | 336 sq ft (31.2 m²) |
| 8 kW | 21 panels | 8.29 kW | 441 sq ft (41.0 m²) |
| 10 kW | 26 panels | 10.27 kW | 546 sq ft (50.8 m²) |
| 12 kW | 31 panels | 12.24 kW | 651 sq ft (60.5 m²) |
Compatible CEC-Listed Inverters for TP7G54M(H)-395
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–14 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.46 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–19 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–12 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–12 panels/string at -10°C | Verify Pair |
Other Power Classes in This Talesun Solar Series (5 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| TP7G54M(H)-400 | 400 W | 371.1 W | 37 V | 13.78 A | 20.49% |
| TP7G54M(H)-405 | 405 W | 375.9 W | 37.25 V | 13.86 A | 20.75% |
| TP7G54M(H)-410 | 410 W | 380.7 W | 37.5 V | 13.94 A | 21% |
| TP7G54M(H)-415 | 415 W | 385.4 W | 37.75 V | 14.02 A | 21.26% |
Engineering FAQ — Talesun Solar TP7G54M(H)-395
How many Talesun Solar TP7G54M(H)-395 panels can fit in one 600V string?
At -10°C (14°F) ambient, the TP7G54M(H)-395 open-circuit voltage rises from 36.75V to 40.66V (using βVoc -0.304%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Talesun Solar TP7G54M(H)-395?
Rated at 395W STC, the TP7G54M(H)-395 carries a 366.3W PTC rating (92.7% PTC/STC ratio) and 20.24% module efficiency across 1.952 m² (21.0 sq ft).
Is the Talesun Solar TP7G54M(H)-395 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.