Tesla Energy TSP-405
405 W, 360 cell monocrystalline module, white backsheet, 1000V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
405W / 380.9W
Efficiency
19.95%
Voc / Vmp
40.87V / 34.15V
Max String (600V)
13 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Tesla Energy |
|---|---|
| Model Number (MPN) | TSP-405 |
| Cell Technology | Mono-c-Si · 108 cells |
| Nameplate Power (Pmax STC) | 405 W |
| Real-World Output (PTC) | 380.9 W (94% of STC) |
| Module Efficiency | 19.95% (199.5 W/m²) |
| Open-Circuit Voltage (Voc) | 40.87 V |
| Maximum Power Voltage (Vmp) | 34.15 V |
| Short-Circuit Current (Isc) | 12.74 A (NEC 1.25× = 15.93 A) |
| Maximum Power Current (Imp) | 11.86 A |
| Temp. Coeff. Power (γPmax) | -0.345 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.261 %/°C |
| Temp. Coeff. Current (αIsc) | +0.045 %/°C |
| Nominal Cell Temp (NOCT) | 42.8 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.03 m² (21.9 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.261%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 40.87 V | 14 | 24 |
| 0°C / 32°F Freezing / Mild Winter | 43.54 V | 13 | 22 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 44.6 V | 13 | 22 |
| -20°C / -4°F Northeast / Midwest Winter | 45.67 V | 13 | 21 |
| -30°C / -22°F Northern Plains / Mountain | 46.74 V | 12 | 21 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.08 kW | 328 sq ft (30.4 m²) |
| 8 kW | 20 panels | 8.10 kW | 437 sq ft (40.6 m²) |
| 10 kW | 25 panels | 10.13 kW | 546 sq ft (50.7 m²) |
| 12 kW | 30 panels | 12.15 kW | 656 sq ft (60.9 m²) |
Compatible CEC-Listed Inverters for TSP-405
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–13 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–10 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.50 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–17 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
Other Power Classes in This Tesla Energy Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| TSP-410 | 410 W | 385.7 W | 40.9 V | 12.83 A | 20.2% |
| TSP-415 | 415 W | 390.6 W | 40.92 V | 12.93 A | 20.44% |
| TSP-420 | 420 W | 395.4 W | 40.95 V | 13.03 A | 20.69% |
| TSP-425 | 425 W | 400.2 W | 40.98 V | 13.12 A | 20.94% |
| TSP-430 | 430 W | 405 W | 41.01 V | 13.2 A | 21.18% |
Engineering FAQ — Tesla Energy TSP-405
How many Tesla Energy TSP-405 panels can fit in one 600V string?
At -10°C (14°F) ambient, the TSP-405 open-circuit voltage rises from 40.87V to 44.6V (using βVoc -0.261%/°C), allowing up to 13 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Tesla Energy TSP-405?
Rated at 405W STC, the TSP-405 carries a 380.9W PTC rating (94% PTC/STC ratio) and 19.95% module efficiency across 2.03 m² (21.9 sq ft).
Is the Tesla Energy TSP-405 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.