Thornova Solar TS-BG54(400)
400 W, 108 half-cut cell double glass bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
400W / 376.1W
Efficiency
20.51%
Voc / Vmp
37.18V / 31.42V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Thornova Solar |
|---|---|
| Model Number (MPN) | TS-BG54(400) |
| Cell Technology | Mono-c-Si (Bifacial) · 108 cells |
| Nameplate Power (Pmax STC) | 400 W |
| Real-World Output (PTC) | 376.1 W (94% of STC) |
| Module Efficiency | 20.51% (205.1 W/m²) |
| Open-Circuit Voltage (Voc) | 37.18 V |
| Maximum Power Voltage (Vmp) | 31.42 V |
| Short-Circuit Current (Isc) | 13.39 A (NEC 1.25× = 16.74 A) |
| Maximum Power Current (Imp) | 12.74 A |
| Temp. Coeff. Power (γPmax) | -0.297 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.234 %/°C |
| Temp. Coeff. Current (αIsc) | +0.03 %/°C |
| Nominal Cell Temp (NOCT) | 46 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.95 m² (21.0 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.234%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 37.18 V | 16 | 26 |
| 0°C / 32°F Freezing / Mild Winter | 39.36 V | 15 | 25 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 40.23 V | 14 | 24 |
| -20°C / -4°F Northeast / Midwest Winter | 41.1 V | 14 | 24 |
| -30°C / -22°F Northern Plains / Mountain | 41.97 V | 14 | 23 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.00 kW | 315 sq ft (29.3 m²) |
| 8 kW | 20 panels | 8.00 kW | 420 sq ft (39.0 m²) |
| 10 kW | 25 panels | 10.00 kW | 525 sq ft (48.8 m²) |
| 12 kW | 30 panels | 12.00 kW | 630 sq ft (58.5 m²) |
Compatible CEC-Listed Inverters for TS-BG54(400)
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–14 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.48 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–19 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–12 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–12 panels/string at -10°C | Verify Pair |
Other Power Classes in This Thornova Solar Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| TS-BG54(405) | 405 W | 380.9 W | 37.33 V | 13.44 A | 20.77% |
| TS-BG54(410) | 410 W | 387.2 W | 37.68 V | 13.59 A | 21.13% |
| TS-BG54(415) | 415 W | 392.1 W | 37.79 V | 13.72 A | 21.39% |
| TS-BG54(420) | 420 W | 396.9 W | 38 V | 13.8 A | 21.65% |
| TS-BG54(425) | 425 W | 401.7 W | 38.21 V | 13.88 A | 21.91% |
Engineering FAQ — Thornova Solar TS-BG54(400)
How many Thornova Solar TS-BG54(400) panels can fit in one 600V string?
At -10°C (14°F) ambient, the TS-BG54(400) open-circuit voltage rises from 37.18V to 40.23V (using βVoc -0.234%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Thornova Solar TS-BG54(400)?
Rated at 400W STC, the TS-BG54(400) carries a 376.1W PTC rating (94% PTC/STC ratio) and 20.51% module efficiency across 1.95 m² (21.0 sq ft).
Is the Thornova Solar TS-BG54(400) listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.