Thornova Solar TS-BGT48(450)-G12R
450 W, 96 half-cut cell double glass bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
450W / 427.9W
Efficiency
22.5%
Voc / Vmp
35.03V / 30.08V
Max String (600V)
15 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Thornova Solar |
|---|---|
| Model Number (MPN) | TS-BGT48(450)-G12R |
| Cell Technology | Mono-c-Si (Bifacial) · 96 cells |
| Nameplate Power (Pmax STC) | 450 W |
| Real-World Output (PTC) | 427.9 W (95.1% of STC) |
| Module Efficiency | 22.5% (225 W/m²) |
| Open-Circuit Voltage (Voc) | 35.03 V |
| Maximum Power Voltage (Vmp) | 30.08 V |
| Short-Circuit Current (Isc) | 16.05 A (NEC 1.25× = 20.06 A) |
| Maximum Power Current (Imp) | 14.97 A |
| Temp. Coeff. Power (γPmax) | -0.293 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.275 %/°C |
| Temp. Coeff. Current (αIsc) | +0.047 %/°C |
| Nominal Cell Temp (NOCT) | 43.2 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2 m² (21.5 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.275%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 35.03 V | 17 | 28 |
| 0°C / 32°F Freezing / Mild Winter | 37.44 V | 16 | 26 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 38.4 V | 15 | 26 |
| -20°C / -4°F Northeast / Midwest Winter | 39.36 V | 15 | 25 |
| -30°C / -22°F Northern Plains / Mountain | 40.33 V | 14 | 24 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 14 panels | 6.30 kW | 301 sq ft (28.0 m²) |
| 8 kW | 18 panels | 8.10 kW | 388 sq ft (36.0 m²) |
| 10 kW | 23 panels | 10.35 kW | 495 sq ft (46.0 m²) |
| 12 kW | 27 panels | 12.15 kW | 581 sq ft (54.0 m²) |
Compatible CEC-Listed Inverters for TS-BGT48(450)-G12R
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 3–15 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 9–12 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8PLUS-72-2-US | Microinverter | 0.295 kW | 97% | 1:1 micro pairing (1.53 DC/AC ratio) | Verify Pair |
| Fronius Primo GEN24 6.0 208-240 Plus SC | Hybrid | 6.005 kW | 97% | 5–15 panels/string at -10°C | Verify Pair |
| GoodWe GEC6.0-1U-US20 | Hybrid | 6.01 kW | 96% | 5–12 panels/string at -10°C | Verify Pair |
| GoodWe GW6000-SBP-US20 | Hybrid | 6.01 kW | 96% | 5–12 panels/string at -10°C | Verify Pair |
Other Power Classes in This Thornova Solar Series (4 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| TS-BGT48(435)-G12R | 435 W | 413.3 W | 34.49 V | 15.9 A | 21.75% |
| TS-BGT48(440)-G12R | 440 W | 418.2 W | 34.67 V | 15.95 A | 22% |
| TS-BGT48(445)-G12R | 445 W | 423 W | 34.85 V | 16 A | 22.25% |
Engineering FAQ — Thornova Solar TS-BGT48(450)-G12R
How many Thornova Solar TS-BGT48(450)-G12R panels can fit in one 600V string?
At -10°C (14°F) ambient, the TS-BGT48(450)-G12R open-circuit voltage rises from 35.03V to 38.4V (using βVoc -0.275%/°C), allowing up to 15 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Thornova Solar TS-BGT48(450)-G12R?
Rated at 450W STC, the TS-BGT48(450)-G12R carries a 427.9W PTC rating (95.1% PTC/STC ratio) and 22.5% module efficiency across 2 m² (21.5 sq ft).
Is the Thornova Solar TS-BGT48(450)-G12R listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.