TSEC TS72-BMH-550 H1
550 W, 144 half-cut cell monocrystalline module, white backhseet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
550W / 510.3W
Efficiency
21.48%
Voc / Vmp
49.8V / 41.95V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | TSEC |
|---|---|
| Model Number (MPN) | TS72-BMH-550 H1 |
| Cell Technology | Mono-c-Si · 144 cells |
| Nameplate Power (Pmax STC) | 550 W |
| Real-World Output (PTC) | 510.3 W (92.8% of STC) |
| Module Efficiency | 21.48% (214.8 W/m²) |
| Open-Circuit Voltage (Voc) | 49.8 V |
| Maximum Power Voltage (Vmp) | 41.95 V |
| Short-Circuit Current (Isc) | 13.98 A (NEC 1.25× = 17.48 A) |
| Maximum Power Current (Imp) | 13.12 A |
| Temp. Coeff. Power (γPmax) | -0.38 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.29 %/°C |
| Temp. Coeff. Current (αIsc) | +0.05 %/°C |
| Nominal Cell Temp (NOCT) | 45.2 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.56 m² (27.6 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.29%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49.8 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 53.41 V | 11 | 18 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 54.85 V | 10 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 56.3 V | 10 | 17 |
| -30°C / -22°F Northern Plains / Mountain | 57.74 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 11 panels | 6.05 kW | 303 sq ft (28.2 m²) |
| 8 kW | 15 panels | 8.25 kW | 413 sq ft (38.4 m²) |
| 10 kW | 19 panels | 10.45 kW | 524 sq ft (48.6 m²) |
| 12 kW | 22 panels | 12.10 kW | 606 sq ft (56.3 m²) |
Compatible CEC-Listed Inverters for TS72-BMH-550 H1
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.43 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This TSEC Series (7 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| TS72-BMH-520 H1 | 520 W | 481.6 W | 48.9 V | 13.59 A | 20.31% |
| TS72-BMH-525 H1 | 525 W | 486.4 W | 49.05 V | 13.65 A | 20.51% |
| TS72-BMH-530 H1 | 530 W | 491.2 W | 49.2 V | 13.71 A | 20.7% |
| TS72-BMH-535 H1 | 535 W | 496 W | 49.35 V | 13.78 A | 20.9% |
| TS72-BMH-540 H1 | 540 W | 500.7 W | 49.5 V | 13.85 A | 21.09% |
| TS72-BMH-545 H1 | 545 W | 505.5 W | 49.65 V | 13.92 A | 21.29% |
Engineering FAQ — TSEC TS72-BMH-550 H1
How many TSEC TS72-BMH-550 H1 panels can fit in one 600V string?
At -10°C (14°F) ambient, the TS72-BMH-550 H1 open-circuit voltage rises from 49.8V to 54.85V (using βVoc -0.29%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the TSEC TS72-BMH-550 H1?
Rated at 550W STC, the TS72-BMH-550 H1 carries a 510.3W PTC rating (92.8% PTC/STC ratio) and 21.48% module efficiency across 2.56 m² (27.6 sq ft).
Is the TSEC TS72-BMH-550 H1 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.