Vikram Solar PREXOS VSMDHT.54.405.05
405 W, 108 half-cut cell bifacial monocrystalline module, transparent backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
405W / 373.6W
Efficiency
21.32%
Voc / Vmp
37.6V / 31.8V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Vikram Solar |
|---|---|
| Model Number (MPN) | PREXOS VSMDHT.54.405.05 |
| Cell Technology | Mono-c-Si (Bifacial) · 108 cells |
| Nameplate Power (Pmax STC) | 405 W |
| Real-World Output (PTC) | 373.6 W (92.2% of STC) |
| Module Efficiency | 21.32% (213.2 W/m²) |
| Open-Circuit Voltage (Voc) | 37.6 V |
| Maximum Power Voltage (Vmp) | 31.8 V |
| Short-Circuit Current (Isc) | 13.4 A (NEC 1.25× = 16.75 A) |
| Maximum Power Current (Imp) | 12.74 A |
| Temp. Coeff. Power (γPmax) | -0.37 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.285 %/°C |
| Temp. Coeff. Current (αIsc) | +0.052 %/°C |
| Nominal Cell Temp (NOCT) | 47.2 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 1.9 m² (20.5 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.285%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 37.6 V | 15 | 26 |
| 0°C / 32°F Freezing / Mild Winter | 40.28 V | 14 | 24 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 41.35 V | 14 | 24 |
| -20°C / -4°F Northeast / Midwest Winter | 42.42 V | 14 | 23 |
| -30°C / -22°F Northern Plains / Mountain | 43.49 V | 13 | 22 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.08 kW | 307 sq ft (28.5 m²) |
| 8 kW | 20 panels | 8.10 kW | 409 sq ft (38.0 m²) |
| 10 kW | 25 panels | 10.13 kW | 511 sq ft (47.5 m²) |
| 12 kW | 30 panels | 12.15 kW | 614 sq ft (57.0 m²) |
Compatible CEC-Listed Inverters for PREXOS VSMDHT.54.405.05
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–14 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.50 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–19 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
Other Power Classes in This Vikram Solar Series (3 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| PREXOS VSMDHT.54.395.05 | 395 W | 364.1 W | 37.4 V | 13.2 A | 20.79% |
| PREXOS VSMDHT.54.400.05 | 400 W | 368.9 W | 37.5 V | 13.3 A | 21.05% |
Engineering FAQ — Vikram Solar PREXOS VSMDHT.54.405.05
How many Vikram Solar PREXOS VSMDHT.54.405.05 panels can fit in one 600V string?
At -10°C (14°F) ambient, the PREXOS VSMDHT.54.405.05 open-circuit voltage rises from 37.6V to 41.35V (using βVoc -0.285%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Vikram Solar PREXOS VSMDHT.54.405.05?
Rated at 405W STC, the PREXOS VSMDHT.54.405.05 carries a 373.6W PTC rating (92.2% PTC/STC ratio) and 21.32% module efficiency across 1.9 m² (20.5 sq ft).
Is the Vikram Solar PREXOS VSMDHT.54.405.05 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.