Yingli Energy Development YL555DF72 e/2
555 W, 144 half-cell monocrystalline PERC module, bifacial, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
555W / 514.7W
Efficiency
22.02%
Voc / Vmp
49.9V / 42.1V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Yingli Energy Development |
|---|---|
| Model Number (MPN) | YL555DF72 e/2 |
| Cell Technology | Mono-c-Si (Bifacial) · 144 cells |
| Nameplate Power (Pmax STC) | 555 W |
| Real-World Output (PTC) | 514.7 W (92.7% of STC) |
| Module Efficiency | 22.02% (220.2 W/m²) |
| Open-Circuit Voltage (Voc) | 49.9 V |
| Maximum Power Voltage (Vmp) | 42.1 V |
| Short-Circuit Current (Isc) | 14.11 A (NEC 1.25× = 17.64 A) |
| Maximum Power Current (Imp) | 13.2 A |
| Temp. Coeff. Power (γPmax) | -0.374 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.274 %/°C |
| Temp. Coeff. Current (αIsc) | +0.026 %/°C |
| Nominal Cell Temp (NOCT) | 45.9 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.52 m² (27.1 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.274%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49.9 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 53.32 V | 11 | 18 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 54.69 V | 10 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 56.05 V | 10 | 17 |
| -30°C / -22°F Northern Plains / Mountain | 57.42 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 11 panels | 6.11 kW | 298 sq ft (27.7 m²) |
| 8 kW | 15 panels | 8.32 kW | 407 sq ft (37.8 m²) |
| 10 kW | 19 panels | 10.54 kW | 515 sq ft (47.9 m²) |
| 12 kW | 22 panels | 12.21 kW | 597 sq ft (55.4 m²) |
Compatible CEC-Listed Inverters for YL555DF72 e/2
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.45 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This Yingli Energy Development Series (4 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| YL540DF72 e/2 | 540 W | 500.4 W | 49.5 V | 13.9 A | 21.43% |
| YL545DF72 e/2 | 545 W | 505.1 W | 49.6 V | 13.97 A | 21.63% |
| YL550DF72 e/2 | 550 W | 509.9 W | 49.8 V | 14.04 A | 21.83% |
Engineering FAQ — Yingli Energy Development YL555DF72 e/2
How many Yingli Energy Development YL555DF72 e/2 panels can fit in one 600V string?
At -10°C (14°F) ambient, the YL555DF72 e/2 open-circuit voltage rises from 49.9V to 54.69V (using βVoc -0.274%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Yingli Energy Development YL555DF72 e/2?
Rated at 555W STC, the YL555DF72 e/2 carries a 514.7W PTC rating (92.7% PTC/STC ratio) and 22.02% module efficiency across 2.52 m² (27.1 sq ft).
Is the Yingli Energy Development YL555DF72 e/2 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.