SEG Solar SEG-460-BTD-HV
460 W, 108 half-cut cell bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
460W / 439.4W
Efficiency
24.34%
Voc / Vmp
39.94V / 34.02V
Max String (600V)
13 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | SEG Solar |
|---|---|
| Model Number (MPN) | SEG-460-BTD-HV |
| Cell Technology | Mono-c-Si (Bifacial) · 108 cells |
| Nameplate Power (Pmax STC) | 460 W |
| Real-World Output (PTC) | 439.4 W (95.5% of STC) |
| Module Efficiency | 24.34% (243.4 W/m²) |
| Open-Circuit Voltage (Voc) | 39.94 V |
| Maximum Power Voltage (Vmp) | 34.02 V |
| Short-Circuit Current (Isc) | 14.18 A (NEC 1.25× = 17.73 A) |
| Maximum Power Current (Imp) | 13.52 A |
| Temp. Coeff. Power (γPmax) | -0.272 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.235 %/°C |
| Temp. Coeff. Current (αIsc) | +0.04 %/°C |
| Nominal Cell Temp (NOCT) | 43.5 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 1.89 m² (20.3 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.235%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 39.94 V | 15 | 25 |
| 0°C / 32°F Freezing / Mild Winter | 42.29 V | 14 | 23 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 43.23 V | 13 | 23 |
| -20°C / -4°F Northeast / Midwest Winter | 44.16 V | 13 | 22 |
| -30°C / -22°F Northern Plains / Mountain | 45.1 V | 13 | 22 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 14 panels | 6.44 kW | 285 sq ft (26.5 m²) |
| 8 kW | 18 panels | 8.28 kW | 366 sq ft (34.0 m²) |
| 10 kW | 22 panels | 10.12 kW | 448 sq ft (41.6 m²) |
| 12 kW | 27 panels | 12.42 kW | 549 sq ft (51.0 m²) |
Compatible CEC-Listed Inverters for SEG-460-BTD-HV
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–13 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7GPLUS-72-2-US | Microinverter | 0.298 kW | 97% | 1:1 micro pairing (1.54 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 4–18 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
Other Power Classes in This SEG Solar Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| SEG-435-BTD-HV | 435 W | 415 W | 39.12 V | 13.86 A | 23.02% |
| SEG-440-BTD-HV | 440 W | 419.9 W | 39.28 V | 13.92 A | 23.28% |
| SEG-445-BTD-HV | 445 W | 424.8 W | 39.44 V | 13.98 A | 23.54% |
| SEG-450-BTD-HV | 450 W | 429.7 W | 39.6 V | 14.04 A | 23.81% |
| SEG-455-BTD-HV | 455 W | 434.5 W | 39.76 V | 14.11 A | 24.07% |
Engineering FAQ — SEG Solar SEG-460-BTD-HV
How many SEG Solar SEG-460-BTD-HV panels can fit in one 600V string?
At -10°C (14°F) ambient, the SEG-460-BTD-HV open-circuit voltage rises from 39.94V to 43.23V (using βVoc -0.235%/°C), allowing up to 13 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the SEG Solar SEG-460-BTD-HV?
Rated at 460W STC, the SEG-460-BTD-HV carries a 439.4W PTC rating (95.5% PTC/STC ratio) and 24.34% module efficiency across 1.89 m² (20.3 sq ft).
Is the SEG Solar SEG-460-BTD-HV listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.