Delta Electronics DWE4150-EV-US (4162.102 kW)
4156 kW, 600Vac, Bi-directional Grid Support Utility Interactive Inverter with Medium-voltage dry-type distribution transformer. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
4162.102 kW
CEC Weighted Eff.
97%
MPPT / Max DC
875–1350V / 1350V
NEC 705.12 Breaker
5100A @ 600V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Delta Electronics |
|---|---|
| Model Number (MPN) | DWE4150-EV-US |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 4162.102 kW (4,162,102 W) |
| Nominal DC Input (Pdco) | 4,294,550 W |
| Nominal AC Voltage | 600 Vac (3-Phase) |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 875 – 1350 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1350 Vdc |
| Max DC Input Current | 3904.1 A |
| Night Tare Loss | 1.73 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 4005.1 A @ 600V |
|---|---|
| 125% Continuous Duty Current | 5006.4 A |
| Minimum Standard Breaker | 5100 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (4578.31–5618.84 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 11446–14047 panels | 4578.4–5618.8 kW DC |
| 440W | 10405–12770 panels | 4578.2–5618.8 kW DC |
| 550W | 8324–10216 panels | 4578.2–5618.8 kW DC |
CEC-Listed 240V Equivalents to Delta Electronics DWE4150-EV-US
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (4162.102 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Delta Electronics DWE4150-EV-US
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 23–23 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 24–24 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 23–23 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-520HT4T {B} | 520 W | 48.9 V | 25–25 per string (-10°C) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | 34–34 per string (-10°C) | Verify Pair |
| REC Solar REC440AA Pure-RX-DC | 440 W | 65.6 V | 19–19 per string (-10°C) | Verify Pair |
Engineering FAQ — Delta Electronics DWE4150-EV-US
What size circuit breaker does the Delta Electronics DWE4150-EV-US require under NEC 705.12?
At 4162.102 kW continuous AC output on 600V (4005.1A continuous), the 125% continuous duty rule requires a minimum 5100A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Delta Electronics DWE4150-EV-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 4162.102 kW unit with 4578.31 kW to 5618.84 kW DC of solar modules without exceeding 1350V cold Voc.