DL CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Delta Electronics E4-TL-US(AC) (3.888 kW)

3840 W, 240 Vac Transformerless Grid Support Utility Interactive Energy Storage Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
3.888 kW
CEC Weighted Eff.
98.5%
MPPT / Max DC
350–480V / 480V
NEC 705.12 Breaker
25A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Delta Electronics E4-TL-US(AC) — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 350–480 Vdc 350V 480V MAX 480V PV DC INPUT ≤ 480V DC 3.888 kW · 98.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 25A BRKR

Electrical & Grid-Support Datasheet

Delta Electronics E4-TL-US(AC) Electrical and Grid-Support Specifications
ManufacturerDelta Electronics
Model Number (MPN)E4-TL-US(AC)
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)3.888 kW (3,888 W)
Nominal DC Input (Pdco)3,948 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency98.5%
MPPT Operating Window350 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current9.9 A
Night Tare Loss1.28 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for E4-TL-US(AC)
Max Continuous AC Current16.2 A @ 240V
125% Continuous Duty Current20.3 A
Minimum Standard Breaker25 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (4.28–5.25 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for E4-TL-US(AC)
Panel ClassRecommended QtyDC Array / Ratio
400W11–13 panels4.4–5.2 kW DC
440W10–12 panels4.4–5.3 kW DC
550W8–10 panels4.4–5.5 kW DC

Engineering FAQ — Delta Electronics E4-TL-US(AC)

What size circuit breaker does the Delta Electronics E4-TL-US(AC) require under NEC 705.12?
At 3.888 kW continuous AC output on 240V (16.2A continuous), the 125% continuous duty rule requires a minimum 25A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Delta Electronics E4-TL-US(AC)?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3.888 kW unit with 4.28 kW to 5.25 kW DC of solar modules without exceeding 480V cold Voc.

More Delta Electronics Inverters

SOLIVIA 3.8 NA G4 TL (3.81 kW)M4-TL-US (3.84 kW)E4-TL-US (3.87 kW)E4_BDI (3.898 kW)M5-TL-US (4.86 kW)E6-TL-US(AC) (5 kW)All Delta Electronics Equipment →