DL CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Delta Electronics E4_BDI (3.898 kW)

3480 W, 240 Vac, transformerless Grid Support Utility Interactive Hybrid Inverter capable of receiving input from EVSE Box with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
3.898 kW
CEC Weighted Eff.
97%
MPPT / Max DC
280–480V / 480V
NEC 705.12 Breaker
25A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Delta Electronics E4_BDI — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 280–480 Vdc 280V 480V MAX 480V PV DC INPUT ≤ 480V DC 3.898 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 25A BRKR

Electrical & Grid-Support Datasheet

Delta Electronics E4_BDI Electrical and Grid-Support Specifications
ManufacturerDelta Electronics
Model Number (MPN)E4_BDI
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)3.898 kW (3,898 W)
Nominal DC Input (Pdco)3,991 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window280 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current10.5 A
Night Tare Loss1.3 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for E4_BDI
Max Continuous AC Current16.2 A @ 240V
125% Continuous Duty Current20.3 A
Minimum Standard Breaker25 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (4.29–5.26 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for E4_BDI
Panel ClassRecommended QtyDC Array / Ratio
400W11–13 panels4.4–5.2 kW DC
440W10–12 panels4.4–5.3 kW DC
550W8–10 panels4.4–5.5 kW DC

Compatible Solar Panels for Delta Electronics E4_BDI

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Delta Electronics E4_BDI
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V8–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — Delta Electronics E4_BDI

What size circuit breaker does the Delta Electronics E4_BDI require under NEC 705.12?
At 3.898 kW continuous AC output on 240V (16.2A continuous), the 125% continuous duty rule requires a minimum 25A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Delta Electronics E4_BDI?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3.898 kW unit with 4.29 kW to 5.26 kW DC of solar modules without exceeding 480V cold Voc.

More Delta Electronics Inverters

M4-TL-US (3.84 kW)E4-TL-US (3.87 kW)E4-TL-US(AC) (3.888 kW)M5-TL-US (4.86 kW)E6-TL-US(AC) (5 kW)SOLIVIA 5.2 NA G4 TL (5.2 kW)All Delta Electronics Equipment →