DL CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Delta Electronics E6-TL-US(AC) (5 kW)

5000 W, 240 Vac, transformerless, Bi-dierctional, Muti-mode Grid Support Utility Interactive Energy Storage Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5 kW
CEC Weighted Eff.
98%
MPPT / Max DC
350–480V / 480V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Delta Electronics E6-TL-US(AC) — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 350–480 Vdc 350V 480V MAX 480V PV DC INPUT ≤ 480V DC 5 kW · 98% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 30A BRKR

Electrical & Grid-Support Datasheet

Delta Electronics E6-TL-US(AC) Electrical and Grid-Support Specifications
ManufacturerDelta Electronics
Model Number (MPN)E6-TL-US(AC)
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)5 kW (5,000 W)
Nominal DC Input (Pdco)5,101 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency98%
MPPT Operating Window350 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current12.8 A
Night Tare Loss2.05 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for E6-TL-US(AC)
Max Continuous AC Current20.8 A @ 240V
125% Continuous Duty Current26.0 A
Minimum Standard Breaker30 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (5.5–6.75 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for E6-TL-US(AC)
Panel ClassRecommended QtyDC Array / Ratio
400W14–17 panels5.6–6.8 kW DC
440W13–15 panels5.7–6.6 kW DC
550W10–12 panels5.5–6.6 kW DC

Engineering FAQ — Delta Electronics E6-TL-US(AC)

What size circuit breaker does the Delta Electronics E6-TL-US(AC) require under NEC 705.12?
At 5 kW continuous AC output on 240V (20.8A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Delta Electronics E6-TL-US(AC)?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5 kW unit with 5.5 kW to 6.75 kW DC of solar modules without exceeding 480V cold Voc.

More Delta Electronics Inverters

E4-TL-US(AC) (3.888 kW)E4_BDI (3.898 kW)M5-TL-US (4.86 kW)SOLIVIA 5.2 NA G4 TL (5.2 kW)E6-TL-US (5.76 kW)M6-TL-US (5.76 kW)All Delta Electronics Equipment →