Delta Electronics M60U_120 (65.47 kW)
60 kW, 480 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
65.47 kW
CEC Weighted Eff.
98.5%
MPPT / Max DC
540–800V / 800V
NEC 705.12 Breaker
100A @ 480V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Delta Electronics |
|---|---|
| Model Number (MPN) | M60U_120 |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 65.47 kW (65,470 W) |
| Nominal DC Input (Pdco) | 66,773 W |
| Nominal AC Voltage | 480 Vac (3-Phase) |
| CEC Weighted Efficiency | 98.5% |
| MPPT Operating Window | 540 – 800 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 800 Vdc |
| Max DC Input Current | 94 A |
| Night Tare Loss | 2.86 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 78.8 A @ 480V |
|---|---|
| 125% Continuous Duty Current | 98.5 A |
| Minimum Standard Breaker | 100 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (72.02–88.38 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 180–221 panels | 72.0–88.4 kW DC |
| 440W | 164–201 panels | 72.2–88.4 kW DC |
| 550W | 131–161 panels | 72.0–88.5 kW DC |
CEC-Listed 240V Equivalents to Delta Electronics M60U_120
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (65.47 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Delta Electronics M60U_120
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Canadian Solar CS6.2-48TM-460H | 460 W | 36.2 V | 21–21 per string (-10°C) | Verify Pair |
| Boviet Solar BVM7609M-435-H-HC-BF | 435 W | 39.23 V | 19–19 per string (-10°C) | Verify Pair |
| REC Solar REC430AA Pure 2 | 430 W | 49 V | 15–15 per string (-10°C) | Verify Pair |
| Maxeon / SunPower SPR-MAX3-435-COM | 435 W | 81.4 V | 9–9 per string (-10°C) | Verify Pair |
Engineering FAQ — Delta Electronics M60U_120
What size circuit breaker does the Delta Electronics M60U_120 require under NEC 705.12?
At 65.47 kW continuous AC output on 480V (78.8A continuous), the 125% continuous duty rule requires a minimum 100A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Delta Electronics M60U_120?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 65.47 kW unit with 72.02 kW to 88.38 kW DC of solar modules without exceeding 800V cold Voc.