Delta Electronics M80U_280 (80.023 kW)
83 kW, 480 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
80.023 kW
CEC Weighted Eff.
98.5%
MPPT / Max DC
550–840V / 840V
NEC 705.12 Breaker
125A @ 480V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Delta Electronics |
|---|---|
| Model Number (MPN) | M80U_280 |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 80.023 kW (80,023 W) |
| Nominal DC Input (Pdco) | 81,416 W |
| Nominal AC Voltage | 480 Vac (3-Phase) |
| CEC Weighted Efficiency | 98.5% |
| MPPT Operating Window | 550 – 840 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 840 Vdc |
| Max DC Input Current | 114.7 A |
| Night Tare Loss | 3.05 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 96.3 A @ 480V |
|---|---|
| 125% Continuous Duty Current | 120.4 A |
| Minimum Standard Breaker | 125 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (88.03–108.03 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 220–270 panels | 88.0–108.0 kW DC |
| 440W | 200–246 panels | 88.0–108.2 kW DC |
| 550W | 160–196 panels | 88.0–107.8 kW DC |
CEC-Listed 240V Equivalents to Delta Electronics M80U_280
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (80.023 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Delta Electronics M80U_280
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| SEG Solar SEG-545-BTC-BG | 545 W | 48.2 V | 16–16 per string (-10°C) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | 21–21 per string (-10°C) | Verify Pair |
| Mission Solar MSX10-445HN0B {C} | 445 W | 38.7 V | 20–20 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.TRON BLK M-G2.D+ 415 | 415 W | 38.47 V | 20–20 per string (-10°C) | Verify Pair |
| Silfab Solar SIL-540XM | 540 W | 47.95 V | 16–16 per string (-10°C) | Verify Pair |
| Canadian Solar CS6.2-48TM-460H | 460 W | 36.2 V | 21–22 per string (-10°C) | Verify Pair |
Engineering FAQ — Delta Electronics M80U_280
What size circuit breaker does the Delta Electronics M80U_280 require under NEC 705.12?
At 80.023 kW continuous AC output on 480V (96.3A continuous), the 125% continuous duty rule requires a minimum 125A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Delta Electronics M80U_280?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 80.023 kW unit with 88.03 kW to 108.03 kW DC of solar modules without exceeding 840V cold Voc.