Deye SUN-12K-SG04LP3-EU (12 kW)
12 kW, 400V 50Hz Hybrid Inverter (IEC 62109 / VDE-AR-N 4105 (EU 3-Phase)). Registry source: Manufacturer IEC Datasheet (Global Reference) · CEC listing date: · Registry snapshot: .
Continuous AC Output
12 kW
CEC Weighted Eff.
97%
MPPT / Max DC
200–650V / 800V
NEC 705.12 Breaker
25A @ 400V
Inverter Engineering Tools
Global / Non-US Reference: Designed for non-US 50Hz / 230V–400V grids; not UL 1741-SB listed for US interconnection.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Deye |
|---|---|
| Model Number (MPN) | SUN-12K-SG04LP3-EU |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 12 kW (12,000 W) |
| Nominal DC Input (Pdco) | 12,371 W |
| Nominal AC Voltage | 400 Vac (3-Phase) |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 200 – 650 Vdc (Manufacturer IEC Datasheet) |
| Max DC Input Voltage | 800 Vdc |
| Max DC Input Current | 26 A |
| Night Tare Loss | 2 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | IEC 62109 / VDE-AR-N 4105 (EU 3-Phase) |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 17.3 A @ 400V |
|---|---|
| 125% Continuous Duty Current | 21.6 A |
| Minimum Standard Breaker | 25 A |
| Busbar Requirement | 200A Busbar (120% rule: up to 40A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (13.2–16.2 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 33–41 panels | 13.2–16.4 kW DC |
| 440W | 30–37 panels | 13.2–16.3 kW DC |
| 550W | 24–29 panels | 13.2–15.9 kW DC |
CEC-Listed 240V Equivalents to Deye SUN-12K-SG04LP3-EU
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (12 kW Hybrid Inverter) and can be added directly to your US System Kit:
Compatible Solar Panels for Deye SUN-12K-SG04LP3-EU
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 6–14 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 6–14 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 6–13 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 6–14 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 6–14 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 5–11 per string (-10°C) | Verify Pair |
Engineering FAQ — Deye SUN-12K-SG04LP3-EU
What size circuit breaker does the Deye SUN-12K-SG04LP3-EU require under NEC 705.12?
At 12 kW continuous AC output on 400V (17.3A continuous), the 125% continuous duty rule requires a minimum 25A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Deye SUN-12K-SG04LP3-EU?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 12 kW unit with 13.2 kW to 16.2 kW DC of solar modules without exceeding 800V cold Voc.