UP CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Univix Power Solutions UVX12KLNA (12 kW)

12.0 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
12 kW
CEC Weighted Eff.
96%
MPPT / Max DC
200–430V / 430V
NEC 705.12 Breaker
70A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Univix Power Solutions UVX12KLNA — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 200–430 Vdc 200V 430V MAX 430V PV DC INPUT ≤ 430V DC 12 kW · 96% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 70A BRKR

Electrical & Grid-Support Datasheet

Univix Power Solutions UVX12KLNA Electrical and Grid-Support Specifications
ManufacturerUnivix Power Solutions
Model Number (MPN)UVX12KLNA
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)12 kW (12,000 W)
Nominal DC Input (Pdco)12,474 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96%
MPPT Operating Window200 – 430 Vdc (NREL SAM Measured)
Max DC Input Voltage430 Vdc
Max DC Input Current34.6 A
Night Tare Loss13.2 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for UVX12KLNA
Max Continuous AC Current50 A @ 240V
125% Continuous Duty Current62.5 A
Minimum Standard Breaker70 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (13.2–16.2 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for UVX12KLNA
Panel ClassRecommended QtyDC Array / Ratio
400W33–41 panels13.2–16.4 kW DC
440W30–37 panels13.2–16.3 kW DC
550W24–29 panels13.2–15.9 kW DC

Compatible Solar Panels for Univix Power Solutions UVX12KLNA

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Univix Power Solutions UVX12KLNA
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–7 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–7 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–6 per string (-10°C)Verify Pair

Engineering FAQ — Univix Power Solutions UVX12KLNA

What size circuit breaker does the Univix Power Solutions UVX12KLNA require under NEC 705.12?
At 12 kW continuous AC output on 240V (50A continuous), the 125% continuous duty rule requires a minimum 70A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Univix Power Solutions UVX12KLNA?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 12 kW unit with 13.2 kW to 16.2 kW DC of solar modules without exceeding 430V cold Voc.

More Univix Power Solutions Inverters

UVX7.6KLNA (7.6 kW)UVX8KLNA (8 kW)UVX10KLNA (10 kW)UVX16LNA (16 kW)UVX5KLNA (5 kW)UVX6KLNA (6 kW)All Univix Power Solutions Equipment →