DY CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Dyness TX7.6K-HM (7.64 kW)

7.6kW, 240Vac output,Bi-directional Transformerless Grid Support Utility Interactive Power Conversion Equipment with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.64 kW
CEC Weighted Eff.
97%
MPPT / Max DC
185–500V / 500V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Dyness TX7.6K-HM — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 185–500 Vdc 185V 500V MAX 500V PV DC INPUT ≤ 500V DC 7.64 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

Dyness TX7.6K-HM Electrical and Grid-Support Specifications
ManufacturerDyness
Model Number (MPN)TX7.6K-HM
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.64 kW (7,640 W)
Nominal DC Input (Pdco)7,890 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window185 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage500 Vdc
Max DC Input Current20.2 A
Night Tare Loss0.12 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for TX7.6K-HM
Max Continuous AC Current31.8 A @ 240V
125% Continuous Duty Current39.8 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.4–10.31 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for TX7.6K-HM
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–23 panels8.4–10.1 kW DC
550W15–19 panels8.3–10.4 kW DC

Compatible Solar Panels for Dyness TX7.6K-HM

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Dyness TX7.6K-HM
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V5–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V5–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V5–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V4–7 per string (-10°C)Verify Pair

Engineering FAQ — Dyness TX7.6K-HM

What size circuit breaker does the Dyness TX7.6K-HM require under NEC 705.12?
At 7.64 kW continuous AC output on 240V (31.8A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Dyness TX7.6K-HM?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.64 kW unit with 8.4 kW to 10.31 kW DC of solar modules without exceeding 500V cold Voc.

More Dyness Inverters

TX6K-HM (6.018 kW)TX6K-AM (6.028 kW)TX7.6K-AM (7.636 kW)TX9.6K-HM (9.648 kW)TX9.6K-AM (9.662 kW)TX11.4K-HM (11.498 kW)All Dyness Equipment →