DY CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Dyness TX9.6K-AM (9.662 kW)

9.6kW, 240Vac output,Bi-directional Transformerless Grid Support Utility Interactive Power Conversion Equipment. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.662 kW
CEC Weighted Eff.
97%
MPPT / Max DC
250–490V / 490V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Dyness TX9.6K-AM — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 250–490 Vdc 250V 490V MAX 490V PV DC INPUT ≤ 490V DC 9.662 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Dyness TX9.6K-AM Electrical and Grid-Support Specifications
ManufacturerDyness
Model Number (MPN)TX9.6K-AM
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)9.662 kW (9,662 W)
Nominal DC Input (Pdco)10,017 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window250 – 490 Vdc (NREL SAM Measured)
Max DC Input Voltage490 Vdc
Max DC Input Current25 A
Night Tare Loss0.12 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for TX9.6K-AM
Max Continuous AC Current40.3 A @ 240V
125% Continuous Duty Current50.4 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.63–13.04 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for TX9.6K-AM
Panel ClassRecommended QtyDC Array / Ratio
400W27–33 panels10.8–13.2 kW DC
440W24–30 panels10.6–13.2 kW DC
550W19–24 panels10.4–13.2 kW DC

Compatible Solar Panels for Dyness TX9.6K-AM

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Dyness TX9.6K-AM
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–9 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — Dyness TX9.6K-AM

What size circuit breaker does the Dyness TX9.6K-AM require under NEC 705.12?
At 9.662 kW continuous AC output on 240V (40.3A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Dyness TX9.6K-AM?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.662 kW unit with 10.63 kW to 13.04 kW DC of solar modules without exceeding 490V cold Voc.

More Dyness Inverters

TX7.6K-AM (7.636 kW)TX7.6K-HM (7.64 kW)TX9.6K-HM (9.648 kW)TX11.4K-HM (11.498 kW)TX11.4K-AM (11.519 kW)TX5K-AM (5.016 kW)All Dyness Equipment →