Enphase Energy official logoCEC-Listed · 240V ResidentialMicroinverter

Enphase Energy IQ6-60-ACM-US (0.23 kW)

230W, 240 Vac Grid Support Utility Interactive Microinverter for ACPV Module applications. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.23 kW
CEC Weighted Eff.
97%
MPPT / Max DC
27–37V / 37V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Enphase Energy IQ6-60-ACM-US — Real Enphase rooftop microinverter hardware
Real Enphase rooftop microinverter hardwareWikimedia Commons — File:Enphase M190.jpg (CC BY-SA 3.0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 27–37 Vdc 27V 37V MAX 37V PV DC INPUT ≤ 37V DC 0.23 kW · 97% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Enphase Energy IQ6-60-ACM-US Electrical and Grid-Support Specifications
ManufacturerEnphase Energy
Model Number (MPN)IQ6-60-ACM-US
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.23 kW (230 W)
Nominal DC Input (Pdco)236 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window27 – 37 Vdc (NREL SAM Measured)
Max DC Input Voltage37 Vdc
Max DC Input Current7.4 A
Night Tare Loss0.03 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for IQ6-60-ACM-US
Max Continuous AC Current1 A @ 240V
125% Continuous Duty Current1.3 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.25–0.31 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for IQ6-60-ACM-US
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (1.74× DC/AC)
440W1 panel1:1 pairing (1.91× DC/AC)
550W1 panel1:1 pairing (2.39× DC/AC)

Engineering FAQ — Enphase Energy IQ6-60-ACM-US

What size circuit breaker does the Enphase Energy IQ6-60-ACM-US require under NEC 705.12?
At 0.23 kW continuous AC output on 240V (1A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Enphase Energy IQ6-60-ACM-US?
As a 230W microinverter, it pairs 1:1 with panels rated roughly 242W to 334W STC.

More Enphase Energy Inverters

IQ7PD-84-2-US (0.21 kW)S230-60-LL-x (0.22 kW)IQ6-60-2-US (0.23 kW)IQ7-60-2-US (0.24 kW)IQ6PLUS-ACB-LL (0.27 kW)S280-60-LL-x (0.27 kW)All Enphase Energy Equipment →