Enphase Energy IQ6PLUS-72-5-US (0.28 kW)
280 W, 240 Vac Grid Support Utility Interactive Microinverter, DC Connector type = 5. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
0.28 kW
CEC Weighted Eff.
97%
MPPT / Max DC
27–45V / 45V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Enphase Energy |
|---|---|
| Model Number (MPN) | IQ6PLUS-72-5-US |
| Inverter Topology | Microinverter |
| Continuous AC Power (Paco) | 0.28 kW (280 W) |
| Nominal DC Input (Pdco) | 289 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 208V, 240V |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 27 – 45 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 45 Vdc |
| Max DC Input Current | 8 A |
| Night Tare Loss | 0.03 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 1.2 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 1.5 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (0.31–0.38 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1 panel | 1:1 pairing (1.43× DC/AC) |
| 440W | 1 panel | 1:1 pairing (1.57× DC/AC) |
| 550W | 1 panel | 1:1 pairing (1.96× DC/AC) |
Compatible Solar Panels for Enphase Energy IQ6PLUS-72-5-US
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Mission Solar MSX10-445HN0B {C} | 445 W | 38.7 V | DC/AC 1.59 (1 panel/input) | Verify Pair |
| Trina Solar TSM-445NEG9RH.25 | 445 W | 35.7 V | DC/AC 1.59 (1 panel/input) | Verify Pair |
| Qcells (Hanwha) Q.TRON BLK M-G2.D+ 445 | 445 W | 40.16 V | DC/AC 1.59 (1 panel/input) | Verify Pair |
| REC Solar REC440AA Pure-RX-DC | 440 W | 65.6 V | DC/AC 1.57 (1 panel/input) | Verify Pair |
| SEG Solar SEG-440-BTE-BG | 440 W | 35.47 V | DC/AC 1.57 (1 panel/input) | Verify Pair |
| Canadian Solar CS6.2-48TM-430H | 430 W | 35 V | DC/AC 1.54 (1 panel/input) | Verify Pair |
Engineering FAQ — Enphase Energy IQ6PLUS-72-5-US
What size circuit breaker does the Enphase Energy IQ6PLUS-72-5-US require under NEC 705.12?
At 0.28 kW continuous AC output on 240V (1.2A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Enphase Energy IQ6PLUS-72-5-US?
As a 280W microinverter, it pairs 1:1 with panels rated roughly 294W to 406W STC.